KitchenAid KWCU405S Product Dimensions Download Page 1

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

CABINET OPENING DIMENSIONS

VENTING REQUIREMENTS

KWCU405S

Electrical:

120-volt, 60-Hz, AC-only, 15-amp.

electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.

Wall-Mount Canopy Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10029780

05-21-07

®

90° elbow

wall
cap

Maximum length  

= 35 ft. (10.7 m)

1 — 90° elbow 

=  5  ft. (1.5 m)

8 ft. (2.4 m) straight  =  8  ft. (2.4 m)
1 — wall cap 

=  0  ft. (0 m)

system length 

=13  ft. (3.9 m)

6 ft. (1.8 m)

2 ft.

(0.6 m)

6" (15.2 cm) vent system

To calculate the length of the system
you need, add the equivalent feet for
each vent piece used in the system.

Note: Flexible vent is Not recommended.

Vent piece 

6" (15.2 cm) round

45° elbow

2.5 feet

(0.8 m)

90° elbow

5.0 feet

(1.5 m)

Non-vented (recirculating) 
chimney dimensions

Vented chimney dimensions

Note:

The hood chimneys are adjustable

and designed to meet varying ceiling or
soffit heights depending on the distance “

X

between the bottom of the hood and the
cooking surface. For higher ceilings, a 40”
(101.6 cm) Chimney Extension Kit No.
8212710 (Stainless Steel), 8212711 (White),
or 8212712 (Black) is available.  The chimney
extension replaces the upper chimney
shipped with the hood. The chimney
extension can be cut as needed. For shorter
ceilings or soffits, the upper chimney can be
cut.

Important:

Minimum distance “

X

”: 24” (61.0 cm)

Suggested maximum distance “

X

”: 

30” (76.2 cm)

For vented installations, the chimneys can
be adjusted for ceilings between 7’ 6-3/8”
(2.30 m) and 9’ 0” (2.74 m).

For non-vented (recirculating) installations,
the chimneys can be adjusted for ceilings
between 8’ 3-3/8” (2.45 m) and 9’ 5-1/4”
(2.88 m).

Important:

As hood height (distance X) increases,
hood's venting effectiveness decreases.

30" (76.2 cm)
36" (91.4 cm)

22" (55.9 cm)

Min 27

¹⁄₂

" (69.8 cm)

Max 36

¹⁄₂

" (92.7 cm)

21

¹⁄₄

" (54 cm)

1

¹⁄₄

"

(3.2 cm)

 

3

¹⁵⁄₁₆

"

(10 cm)

10

¹⁄₄

" (26 cm)

11

¹³⁄₁₆

" (30 cm)

30" (76.2 cm)
36" (91.4 cm)

22" (55.9 cm)

Min 32" (81.3 cm)
Max 38

¹⁄₈

" (96.8 cm)

22"

(55.9 cm)

1

¹⁄₄

"

(3.2 cm)

 

3

¹⁵⁄₁₆

"

(10 cm)

10

⁵⁄₈

" (27 cm)

12" (30.5 cm)

12

¹⁄₂

"

(31.8 cm)

 

5"

(12.7 cm)

3

¹⁄₂

"

(8.9 cm)

 

18" (45.7 cm) min. 
clearance upper 
cabinet to countertop

X*

36" (91.4 cm) 
countertop height

See Note*

30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(if installed between cabinets)

Roof Venting

Wall Venting

Non-vented 
(recirculating)

A. Roof cap
B. 6" (15.2 cm) 

round vent

A. Wall cap
B. 6" (15.2 cm) 

round vent

A. Deflector
B. 6" (15.2 cm) 

round vent

A

A

B

B

B

A

Reviews: