 It is recommended that you use round vent instead of rectangular 
vent, especially if elbows are required. 

For best performance, use no more than three 90° elbows. If more 
than one elbow is used, make sure that there is a minimum of 24 
inches (61 cm) of straight vent between any two elbows. Do not 
install two elbows together.

 

To calculate the length of system you need, add the equivalent 
feet (meters) from chart below for each vent piece that will be 
needed.

PRODUCT MODEL NUMBERS

KHTU705R
KHTU765R

Electrical:

 120-V, 60-Hz, AC-only, 15 amp. 

electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is 
recommended.

INSTALLATION CLEARANCES

OVERALL DIMENSIONS

30

 and 36

 Range Hoods

 Because Whirlpool Corporation policy includes a continuous commitment to improve
 our products, we reserve the right to change materials and specifi cations without notice.

 Dimensions are for planning purposes only.  For complete details, see Installation 

Instructions packed with product.  Specifi cations subject to change without notice.

30”(76.2 cm) or

36” (91.4 cm) min.

cabinet opening width

24” (61 cm) min.

30” (76.2 cm)

suggested max. 

bottom of hood

to cooking surface

18” (45.7 cm) 
min. clearance 
upper cabinet 
to countertop

36” (91.4 cm)

countertop

height

70 

⁵⁄₁₆

(178.6 cm) 

min. 

76 

⁵⁄₁₆

(193.8 cm)

max.

to bottom of

cabinet frame

VENT AND ELECTRICAL OPENINGS AND MOUNTING 
SCREW LOCATIONS

⁷⁄₈

" (14.9 cm) dia.

exhaust collar

Interchangeable 
front trim

9

 ¹⁵⁄₁₆

"

(25.2 cm)

20 

³⁄₁₆

(51.3 cm)

29 

¹⁵⁄₁₆

” (76.0 cm) - 30” (76.2 cm) model

35 

¹⁵⁄₁₆

” (91.3 cm) - 36” (91.4 cm) model

1

¹⁄₄

(3.2 cm)

1

⁵⁄₁₆

(3.3 cm)

5

⁷⁄₈

(14.9 cm)

dia.

Centerline of 
exhaust collar

9

¹⁄₈

(23.2 cm)

1

³⁄₁₆

(3.0 cm)

3

⁵⁄₁₆

(10.0 cm)

7

¹⁄₂

(19.0 cm)

Electrical
knockouts

1

⁵⁄₁₆

(3.3 cm)

Centerline of 

hood

VENTING REQUIREMENTS

This range hood is factory set for vented installations. Vent system 
can terminate through either the roof or a wall. The vent system 
length should not exceed 35 ft (10.7 m)

Determine the length of the vent system you need

To calculate the length of the vent system you need, add the 
equivalent feet (meters) from chart below for each vent piece that 
will be needed.

Recommended standard 6

 

(15.2 cm) fi ttings

Ref. 9763384
       09-11-06

1 ft. round=
1 ft. (0.3 m)

90° elbow=
5 ft. (1.5 m)

45° elbow=
2.5 ft. (0.8 m)