Page 1: ...d _vacuation 18 Installation des pieds de nivellement 18 Mise h niveau de la s_cheuse 18 Conduit d _vacuation 18 Inversion de I ouverture de la porte 19 Achever I installation 20 DRYERSAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert sy...

Page 2: ...atures the dryer might not shut off at the end of an automatic cycle Drying times can be extended Install the dryer where it is protected from water and or weather Check code requirements Some codes limit or do not permit installation of the dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Installation Clearances The location must be large enough to ...

Page 3: ...Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA To supply the required 4 wire single phase 115 230 volt 60 Hz AC only electrical supply on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a stand...

Page 4: ...t looks like this If your outlet looks like this 3 wire receptacle 10 30R Then choose a 3 wire power supply cord with ring or spade terminals and UL approved strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have 3 No 10 copper wires and match a 3 wire receptacle of NEMA Type 10 30R If connecting by direct wire Power supply cable must match power supply 4 wire or 3 wire and...

Page 5: ... block opening Fire Hazard Use 10 gauge somid copper wire Use a UL approved strain relief Disconnect power before making emectrical connections Connect neutral wire white or center wire to center terminal simver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 suppmy wires to remaining 2 terminals goJd Securely tighten aimemectrica connections Failure ...

Page 6: ...nals with upturned ends 6 3 4 in 1 9 cm UL approved strain relief 7 Ring terminals 1 Remove center terminal block screw 2 Remove appliance ground wire green with yellow stripes from external ground connector screw Fasten it under center silver colored terminal block screw 1 2 0 1 External ground connector Dotted line shows position of NEUTRAL ground wire before being moved to center terminal block...

Page 7: ...inal block screw 3 Green yellow wire of harness Connect ground wire green or bare of power supply cable to external ground conductor screw Tighten screw Place the hooked end of the neutral wire white or center wire of power supply cable under the center screw of terminal block hook facing right Squeeze hooked end together Tighten screw _jf 2 3 4 5 1 6 1 in 1 9 cm UL listed strain relief 2 Green wi...

Page 8: ...facing right squeeze hooked end together and tighten screw See example below 1 2 Loosen or remove center terminal block screw Place the hooked end of the neutral wire qwhite or center wire of power supply cable under the center screw of terminal block hook facing right Squeeze hooked end together Tighten screw 2 3 f 1 Neutral grounding wire green yellow 2 External ground connector 3 Center silver ...

Page 9: ... fully extended and supported when the dryer is in its final position Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance An exhaust hood should cap the vent to prevent rodents and insects from entering the home Exhaust hood must be at least 12 in 30 5 cm from the ground or any object that may be in the path of the exhaust such as ...

Page 10: ...the mobile home Terminate the exhaust vent outside f Determine Vent Length 1 Select the route that will provide the straightest and most direct path outdoors Plan the installation to use the fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking Avoid 90 turns etJJ Determine vent length The maximum length of the exhau...

Page 11: ...ct the exhaust vent 6 Once connection is made and dryer is in final location remove corner posts and cardboard Check the levelness of the dryer Check levelness first side to side then front to back If the dryer is not level prop up the dryer using a wood block Use a wrench to adjust the legs up or down and check again for levelness NOTE It might be necessary to level the dryer again after it is mo...

Page 12: ...ttom of slots Tighten screws Insert and tighten top screws in hinges 10 Remove door strike plug 2 Insert the door strike you removed in Step 8 in hole and secure with screw Insert door strike plug in original door strike hole and secure with screw 11 Close door and check that door strike aligns with door catch 3 If needed slide door catch left or right within slot to adjust alignment 1 Check to be...

Page 13: ...out le necessaire pour une installation convenable C est a I utilisateur qu incombe la responsabilite d assurer une installation convenable Tournevis a lame plate Cle molette avec ouverture jusqu a 1 po 2 54 cm ou cle a douille hexagonale pour ajuster les pieds de la secheuse Niveau Pince a denuder Pour les installations raccordement direct aux I2 U seulement Tournevis Phillips n 2 Lunettes de sec...

Page 14: ...nt ou n autorisent pas I installation des secheuses darts un garage un placard une maison mobile ou une chambre a coucher Communiquer avec I inspecteur des b timents local Espacements d installation L emplacement dolt _tre assez grand pour permettre d ouvrir completement la porte de la secheuse 26 66 _m J t5W 38 74 cm 43 _ s 110 m 29 _ _ 73 66 crn 3 110 m 27 314 1 Porte 9 pivotement lateral b peti...

Page 15: ...ble temporise ou disjoncteur On recommande egalement que cet appareil soit alimente par un circuit independant Cette secheuse est equip6e d un cordon electrique homologue par la CSA International a introduire dans une prise murale standard 14 30R Le cordon mesure 5 pi 1 52 m de long Veiller ace que la prise murale se trouve proximite de I emplacement definitif de la secheuse Prise murale a 4 ills ...

Page 16: ...allique Iourd Ne pas utiliser un conduit de plastique ou en feuille metallique On recommande d utiliser un conduit metallique rigide pour reduire les risques d ecrasement et de deformation Un conduit metallique souple dolt _tre totalement deploye et soutenu Iorsque la secheuse est a sa position finale Enlever tout exces de conduit souple pour eviter tout affaissement et deformation susceptible de ...

Page 17: ... de type botte Le clapet incline illustre ci dessous est acceptable Consulter le tableau correspondant au type de clapet de decharge utilise pour determiner la Iongueur maximale de conduit utilisable Si la Iongueur du circuit est superieure la valeur specifiee dans le tableau on observera Une reduction de la Iongevite de la secheuse Une reduction du rendement avec temps de sechage plus long et plu...

Page 18: ... dans le sens avant arriere Risque du poids exceseif UtiHser deux ou pmuede personnes pour deplacer et installer masecheuse Le non respect de cette instruction peut causer une bmeseure au doe ou d autre Messure 1 Pour proteger le sol utiliser un grand morceau de I emballage en carton de la secheuse Placer le carton sous le bord arriere de la secheuse Voir I illustration 2 Saisir fermement la seche...

Page 19: ...a porte vers la gauche ou la droite dans son Iogement pour ajuster I alignement 6 Placer une serviette 1 sur la secheuse pour proteger la surface Ouvrir la porte de la secheuse 0ter les vis inferieures fixant les charnieres 4 sur la caisse Desserrer sans les 6ter les vis superieures fixant les charnieres sur la caisse 3 Soulever la porte suffisamment pour que les vis superieures de la caisse se tr...

Page 20: ... reliee a la terre Mettre le courant 7 Retirer la pellicule de protection bleue sur le panneau de commande et le ruban reste sur la secheuse 8 Lire Instructions d utilisation de la secheuse 9 Essuyer soigneusement le tambour de la secheuse avec un chiffon humide pour eliminer toute trace de poussiere 10 Regler la secheuse sur un programme de sechage complet pas le programme de sechage sans chaleur...