Page 1: ...ionnel 9 D_pose de la porte du four 10 Raccordement electrique 10 Installation du four 11 Achever I installation 12 BUILT IN MICROWAVE OVENCOMBINATION SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to po...

Page 2: ...clearance with oven Recessed installation area must provide complete enclosure around the recessed portion of the oven Grounded electrical supply is required See Electrical Requirements section Electrical supply junction box should be located 3 7 6 cm maximum below the support surface when the oven is installed in a wall cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the righ...

Page 3: ...adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No O M91 1atest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cle...

Page 4: ...an result in back or other injury 2 To avoid floor damage set the oven onto cardboard prior to installation Do not use handle or any portion of the front frame for lifting 3 Remove the shipping materials and tape from the oven 4 Remove the hardware package from inside the bag containing literature 5 Remove and set aside racks and other parts from inside the oven 6 Move oven and cardboard close to ...

Page 5: ...her using a UL listed wire connector 3 Untwist white wire from green or bare ground wire coming from the oven 4 Connect the 2 white wires F together using a UL listed wire connector 5 Connect the green or bare ground wire H from the oven cable to the green or bare ground wire in the junction box using a UL listed wire connector 6 Install junction box cover D E F A Cable from home power supply B Ju...

Page 6: ...E appears in the lower oven display touch START 3 Touch BROIL 4 Touch START If oven does not operate check the following Household fuse is intact and tight or circuit breaker has not tripped Electrical supply is connected See Troubleshooting section in the Use and Care Guide 5 When oven has been on for 5 minutes feel for heat If you do not feel heat or if an error code F followed by a number plus ...

Page 7: ...eau Pi_ces n_cessaires Connecteur de conduit homologation UL ou CSA Cennecteurs deills homelegation UL Pi_ces fournies Vis n 8 14 x 1 four simple 2 four double 4 Event du fond fourni sur certains modeles Deux vis n 8 18 x 3 8 event du fond fourni sur certains modeles Consulter les codes Iocaux V ifier I alimentation electrique existante Voir Specifications electriques II est recommande de faire re...

Page 8: ... B 2 5 cm entre le sommet de I ouverture et le bas de la porte du placard sup_rieur C 19V4 48 9 cm entre le bas de I ouverture et le plancher D Largeur de I ouverture 25F2 64 8 cm E 1F2 3 8 cm min entre le bas de I ouverture et le haut de la porte du placard F Hauteur de I ouverture 41_ 4 04 8 cm Mod les de 30 76 2 cm A Largeur du placard 30 76 2 cm min B 2 5 cm entre le sommet de I ouverture et l...

Page 9: ... distribution par un c ble a conducteur de cuivre et gaine metallique flexible ou gaine non metallique avec conducteur de liaison la terre Voir la section Raccordement electrique Le c ble blinde flexible de I appareil dolt _tre connecte directement dans le bottler de connexion Installer un fusible pour chaque fil de phase Ne pas couper le conduit La Iongueur du conduit fournie est destinee a facil...

Page 10: ...de conduit 7 Voir Tableau des options de raccordement electrique pour terminer I installation correspondant a votre type de raccordement electrique Tableau des options de raccordement _lectrique C blage de la maison Voir la section 4 conducteurs C ble 4 conducteurs depuis le point de distribution du domicile Risque de choc electrique Deconnecter la source de courant electrique avant d entreprendre...

Page 11: ... terre depuis le four F Cable flexible a 4 conducteurs depuis le four G Conducteurs rouges H Connecteurs de ills homolegation UL I Connecteur de conduit homelogation UL ou CSA f Connecter ensemble les 2 conducteurs noirs C avec un connecteur de ills homologation UL 2 Connecter les 2 conducteurs blancs D et le conducteur vert ou nu de liaison a la terre du c ble du four avec un connecteur de ills h...

Page 12: ...lench La prise de courant est correctement alimentee Voir la section Depannage dans le Guide d utilisation et d entretien Apr_s 5 minutes de fonctionnement du four v ifier I emission de chaleur Si aucune emission de chaleur n est perceptible ou si un code d anomalie F suivi d un chiffre plus E suivi d un chiffre apparait sur I afficheur interrompre I alimentation du four et contacter un technicien...