5-2
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-3 for the procedure for servic-
ing an element and limiter.
1.
Disconnect power to the cooktop.
2.
Disconnect the main wiring harness con-
nectors from the element and limiter termi-
nals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate as shown:
Element terminals 1 & 2 = 41 to 56
Ω
.
Limiter terminals 2 & 3 = 0
Ω
.
RF & LR ELEMENTS
1
2
3