5-1
COMPONENT TESTING
When testing any of the components, be sure
to observe the following conditions:
• Disconnect the power to the cooktop before
removing the unit from its mounting location.
• Make sure that all wires are properly con-
nected before operating the cooktop.
• Grasp the wires by their connectors when
removing them from the element and limiter
terminals.
Refer to page 4-3 for the procedure for servic-
ing an element and limiter.
1.
Disconnect power to the cooktop.
2.
Disconnect the main wiring harness con-
nectors from the element and limiter termi-
nals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate as shown:
Element terminals 1 & 2 = 35 to 46
Ω
.
Element terminals 2 & 3 = 52 to 64
Ω
.
Limiter terminals 2 & 4 = 0
Ω
.
LF (DUAL) ELEMENT
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
RR (DUAL) ELEMENT
1 2 3
Refer to page 4-3 for the procedure for servic-
ing an element and limiter.
1.
Disconnect power to the cooktop.
2.
Disconnect the main wiring harness con-
nectors from the element and limiter termi-
nals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate as shown:
Element terminals 1 & 2 = 65 to 80
Ω
.
Element terminals 2 & 3 = 50 to 65
Ω
.
Limiter terminals 2 & 4 = 0
Ω
.
4
1 2
3
4
Summary of Contents for KECC508MBL
Page 4: ... iv NOTES ...
Page 11: ...2 1 INSTALLATION INFORMATION PRODUCT DIMENSIONS ...
Page 12: ...2 2 CUTOUT DIMENSIONS REQUIREMENTS ...
Page 16: ...2 6 NOTES ...
Page 35: ...7 5 TERMINAL BLOCK CONNECTIONS ...
Page 36: ...7 6 NOTES ...
Page 37: ...7 7 NOTES ...
Page 38: ...7 8 NOTES ...
Page 40: ......