4-4
REMOVING THE USER INTERFACE AND
ELECTRONIC CONTROL BOARDS
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1.
Disconnect power to the cooktop.
2.
Remove the cooktop glass from the burner
base (see page 4-2 for the procedure).
3.
To remove the user interface board:
a) Lift the board assembly and rotate it on
its left side.
b) Pull the edge connector off the left side
of the user interface board and remove
the board.
User Interface Board
Edge Connector
c) Pull the nine springs off the posts of the
plastic light shield.
d) Unsnap the four latching tabs on the
plastic light shield from the board and
remove the board from the shield.
Spring (1 of 9)
Latching Tab
(1 of 4)