KitchenAid KECC051HBL0 Installation Instructions Manual Download Page 2

Panel A

36" (91.4 cm) or 30" (76.2 cm) min. base
cabinet 
is required. If cabinet has a drawer, a 
3" (7.5 cm) depth clearance from the countertop
to the top of the drawer (or other obstruction) in
the base cabinet is required.

Before you start...

Product dimensions

Cutout dimensions/requirements

Junction box,
12" (30.5 cm)
or more above
floor and 10"
(25.4 cm) from
right side of
cabinet.

Copies of the standards listed may be obtained from:

** National Fire Protection Association

Batterymarch Park
Quincy, Massachusetts 02269

*** Canadian Standard Association

178 Rexdale Boulevard 
Etobicoke, (Toronto), Ontario M9W 1R3

Your safety and the safety of others 

is very important.

We have provided many important safety messages
in this manual and on your appliance. Always read
and obey all safety messages.

This is the safety alert symbol. This symbol
alerts you to hazards that can kill or hurt

you and others. All safety messages will be
preceded by the safety alert symbol and the word
“DANGER” or “WARNING”. These words mean:

All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the instructions are not
followed.

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

WARNING

DANGER

Proper installation is your responsibility. Make
sure you have everything for correct installation.
It is the responsibility of the installer to comply
with the installation clearances specified in these
instructions.

Cooktop installed over oven installation: Only
certain specified cooktop and oven models are
approved for cooktop over oven installations.
Cooktops approved for this type of installation
will have an approval label located on the outside
of the burner box. If you do not find this label,
contact your dealer to confirm that cooktop is
approved. The label on the bottom of your
cooktop lists the cooktop and oven combinations
that are approved for this type of installation.

Ovens approved for this type of installation will
have an approval label located on top of oven. If
you do not find this label, contact dealer to
confirm that oven is approved. Refer to oven
manufacturer’s Installation Instructions for
approval for built-under use and proper cutout
dimensions.

When installing cooktop over a built-under
oven
, Do Not fasten cooktop to countertop with
clamps. Cooktop then will be easy to remove if
servicing is ever necessary.

Check location where cooktop will be installed.
The location should be away from strong draft
areas, such as windows, doors and strong
heating vents or fans. The cooktop should be
located for convenient use in the kitchen.

Grounded electrical supply is required. See
“Electrical requirements,” Panel B.

Important:
Observe all governing codes and ordinances.
Failure to meet governing codes and
ordinances could lead to fire or electrical
shock.

When installing a cooktop under existing
cabinets and the installation does not meet the
minimum cabinet clearances. Install a range
hood above the cooktop to avoid burn hazards.

Countertop opening dimensions that are
shown must be used. Given dimensions are
minimum clearances and provide required 0" 
(0 cm) clearance.

New installations — follow minimum
dimensions given.

Replacement installations — Be sure that 
front edge of cooktop is at least 1-1/2" 
(3.8 cm) back from front edge of countertop.

It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest
edition**, or CSA Standards 
C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 - latest edition *** and all
local codes and ordinances.

2-7/8" (7.3 cm)

burner box

height

21" (53.3 cm) depth 

21-5/16" (54.1 cm) depth 

30" (76.2 cm) or 
36" (91.4 cm) width

15" (38.1 cm)
30" (76.2 cm) or 
36" (91.4 cm) width

3/4" (1.9 cm)
both sides

2-3/4" (7.3 cm)

burner box

height

20-1/2"

(52 cm)

18" (45.7 cm) min.

clearance upper

cabinet to countertop

within minimum

clearances to cooktop

Do not seal
cooktop to
countertop.

2" min.
(5.1 cm)

13" (33 cm)

recommended

upper cabinet

depth

Cooktop width

A

B

15" 14-1/2"

15"

(38.1 cm)

(36.6 cm)

(38.1 cm)

30" 29-1/2" 

30"

(76.2 cm)

(75 cm)

(76.2 cm)

36" 35-1/2" 

36"

(91.4 cm) 

(90.2 cm)

(91.4 cm)

1" (2.5 cm) min. distance to

nearest left and right side

combustible surface above

cooktop.

See NOTE*
for minimum
clearances.

*

Note: 24" (61 cm) min.

clearance if bottom of wood or
metal cabinet is protected by
not less than 1/4" (0.6 cm)
flame retardant millboard
covered with not less than No.
28 MSG sheet steel, 0.015"
(0.04 cm) stainless steel, or
0.024"(0.06 cm) aluminum or
0.020" (0.05 cm) copper.

30" (76.2 cm) min. clearance
between top of cooking
platform and bottom of
unprotected wood or metal
cabinet.

Tools needed for installation:

flat-blade
screwdriver

pencil

pliers

ruler or 
tape measure

Summary of Contents for KECC051HBL0

Page 1: ...ons for future reference Save Installation Instructions for local electrical inspector s use Write down the model and serial numbers before installing cooktop Both numbers are on the model serial rating plate located on the bottom of the cooktop Model ________________ Serial _______________ IMPORTANT Read and save these instructions Part No 3192799 15 38 1 cm 30 76 2 cm and 36 91 4 cm Electric Bui...

Page 2: ...cooktop over a built under oven Do Not fasten cooktop to countertop with clamps Cooktop then will be easy to remove if servicing is ever necessary Check location where cooktop will be installed The location should be away from strong draft areas such as windows doors and strong heating vents or fans The cooktop should be located for convenient use in the kitchen Grounded electrical supply is requi...

Page 3: ...nction box through the U L or C S A listed conduit connector Complete electrical connection according to local codes and ordinances WARNING Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Canadian Standard Association 178 Rexdale Boulevard Etobicoke Toronto Ontario M9W 1R3 Electrical Shock Hazard Turn power suppl...

Page 4: ...the countertop Center the cooktop in the cutout Check that the front of the cooktop is parallel to the front edge of the countertop Check that all required clearances are met If cooktop is not properly positioned lift the cooktop off the countertop to make adjustments 1 Remove the shipping materials and tape from the cooktop Remove the hardware package from inside the literature bag 3 Insert one c...

Page 5: ...la terre Ne pas utiliser une canalisation de gaz pour la liaison à la terre En cas de doute en ce qui concerne la liaison à la terre de la table de cuisson contacter un électricien qualifié Ne pas installer de fusible dans le circuit de liaison à la terre ou dans le fil neutre IMPORTANT Conserver les Instructions d installation pour l utilisation par l inspecteur local des installations électrique...

Page 6: ...table de cuisson au dessus du comptoir en serrant chaque vis à la main ensuite utiliser un tournevis pour serrer chaque vis de 1 à 1 1 2 tour de plus Ne pas serrer les vis excessivement 7 Selon le modèle que vous avez appuyer sur chaque bouton de commande et le tourner à la position HI ou appuyer sur ON et tourner chaque bouton de commande à la position HI Vérifier le bon fonctionnement des élémen...

Page 7: ...ien pour un numéro de téléphone sans frais d interurbain ou téléphoner au marchand où vous avez fait l achat de cet appareil électroménager Le marchand est indiqué dans les Pages jaunes de votre annuaire téléphonique sous la rubrique Appareils électroménagers Si vous avez besoin de service Conserver la qualité incorporée dans votre table de cuisson en communiquant avec une compagnie de service aut...

Reviews: