5-2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
POWER SUPPLY TRANSFORMER
CROWN BURNER SWITCH
Refer to page 4-3 for the procedure for access-
ing the Crown burner switch.
1. Unplug cooktop or disconnect power.
2. Disconnect the wire connectors from the
switch terminals.
3. Set the Crown burner to the OFF position.
4. Set the ohmmeter to R x 1.
5. Touch the ohmmeter test leads to the switch
terminals. The meter should indicate an open
circuit (infinite)
.
6. Set the Crown burner to the LITE position.
The meter should indicate a closed circuit
0
Ω
Refer to page 4-6 for the procedure for access-
ing the power supply transformer.
1. Unplug cooktop or disconnect power.
2. Disconnect the power supply transformer
primary (2-pin) connector.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the trans-
former connector pins. See transformer
table below.
Switch (N.O.)
Primary Connector
TRANSFORMER TABLE
S
N
O
I
T
I
D
N
O
C
S
T
I
N
U
P
Y
T
T
S
E
T
E
C
N
A
T
S
I
S
E
R
Rp
Primary Coil
Resistance
60
±
6
Ω
22 °C
Rs 1-2
Secondary Coil
Resistance
4.7 ± 0.5
Ω
22 °C
Rs 2-3
Secondary Coil
Resistance
4.7 ± 0.5
Ω
22 °C
Rs 4-5
Secondary Coil
Resistance
306 ± 30
Ω
22 °C