Flame Height Adjustment
Each burner flame has been factory set to the
lowest position available to provide reliable and
constant reignition of the burner; however, each
burner can be adjusted.
To Adjust:
The flame can be adjusted using the adjustment
screws underneath the control knob.
A. Single valve
B. Dual valve
A
A
A
A
B
Adjustment for Single Valve
1. Set the burner flame to LO.
2. Remove the control knob.
3. Hold knob stem with a pair of pliers. Use a
3/32" (#0 [2.0 mm]) flat blade screwdriver
to turn the screw located within the shaft
of the control knob stem until the flame is
the proper size.
A.
�⁄��
" (#0 [2.0 mm]) flat blade screwdriver
(screwdriver shaft must be a minimum of
1
�⁄�
" (28.0 mm) long)
B. Control knob stem opening
C. Adjustment screw location
B
C
A
4.
For LP gas conversion:
Completely tighten screw “C” to set the
minimum flame height.
For Natural gas conversion:
Tighten screw “C” to reduce flame height.
Loosen screw to increase flame height. See
“Complete Burner Adjustment” section.
5. Replace the control knob.
6. Test the flame by turning the control from
LO to HI, checking the flame at each
setting.
Adjustment for Dual Valve
To Adjust Inner Crown Flame:
1. Set the inner crown flame to LO.
A. Inner crown
B. Outer crown
A
B
2. Remove the control knob.
3. Remove the black rubber grommet.
4. Using needle-nose pliers, remove the gray
shield inside the burner valve opening.
A. Control knob
B. Black rubber grommet
C. Gray shield
Med
A
B
C