2-9
Adjust Flame Height
The surface burner “low” flame should be a
steady blue flame approximately 1/4" (0.64
cm) high.
A. Low flame
B. High flame
A
B
If the “low” flame needs to be adjusted:
The flame can be adjusted using the adjustment
screws underneath the control knob.
A. Single valve
B. Dual valve
A
A
A
A
B
Adjustment for Single Valve:
1. Set the burner flame to LO.
2. Remove the control knob.
3. Hold knob stem with a pair of pliers. Use
a 3/32" (#0 [2 mm]) flat blade screwdriver
to turn the screw located within the shaft
of the control knob stem until the flame is
the proper size.
Turn adjustment screw “C” to the right to reduce
flame height, turn adjustment screw to the left
to increase flame height.
A.
�⁄��
" (#0 [2.0 mm]) flat blade screwdriver
(screwdriver shaft must be a minimum of
1
�⁄�
" (28.0 mm) long)
B. Control knob stem opening
C. Adjustment screw location
B
C
A
4. Replace the control knob.
5. Test the flame by turning the control from
LO to HI, checking the flame at each set
-
ting
Adjustment for Dual Valve:
1. Set the inner crown flame to LO.
A. Inner crown
B. Outer crown
A
B