ADJUSTMENTS & EFFICIENCY
Section Three:
INSTALLER FINAL CHECKLIST
Section Three:
FIG.18
BURNER AIR ADJUSTMENT:
Each grill burner is tested and adjusted at the factory
prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burners.
The flames of the burners should be visually checked
and compared with Figure 18.
Flames should be blue and stable with no yellow tips,
excessive noise or lifting. If any of these conditions
exist, check if the air shutter or burner ports are
blocked by dirt, debris, spider webs, etc. Proceed with
air shutter adjustment.
The amount of air which is entrained into a burner is
governed by a sheetmetal cup at the inlet of the burner
called an air shutter. It is locked in place by a set screw
which must be loosened prior to lighting the burner
for adjustment.
The air shutter adjustment screws are accessible with a
screw driver. Remove the burner by loosening the wing
nut as shown (fig. 18). Loosen the lock screw of the air
shutter.
MAKE CERTAIN THAT THE BURNERS ARE
SITTING PROPERLY ON THE ORIFICES AND LIGHT
THE BURNERS
. Adjust according to the following
directions.
TO ADJUST GRILL BURNER FLAME:
BE CAREFUL AS THE BURNER MAY BE VERY HOT.
If the flame is yellow, indicating insufficient air, turn the
air shutter counter-clockwise to allow more air to the
burner.
If the flame is noisy and tends to lift away from the
burner, indicating too much air, turn the air shutter
clockwise.
❑
Specified clearances maintained 24” from
combustibles.
❏
All internal packaging removed.
❏
Knobs turn freely.
❏
Burners are sitting properly on orifices.
❏
Each burner lights satisfactorily, individually or with
adjacent burner lit.
❏
Air shutters adjusted.
❏
Pressure regulator connected and set for 11.2" W.C.
LP gas. Gas connections to grill using hose &
regulator assembly provided (pre-set for 11.0” water
column).
❏
Unit tested and free of leak
s.
❏
User informed of gas supply shut off valve location.
USER, PLEASE RETAIN THESE
INSTRUCTIONS FOR FUTURE REFERENCE