6 .4 .13 Adjusting the Intensity of Currents
X
NOTE
Z
Read the data sheet which is delivered with xenon bulb. The bulb manufacturer’s
own data should be used.
Z
Read also rectifier’s operating manual.
The intensity of currents associated to the installed xenon bulb can be adjusted on the
rectifier. The control can be operated by a potentiometer, a hand wheel, bridges, etc.
Lamp Capacity [W] Typical Current [A] Max . Current [A]
1000
50
55
1600
65
70
2000
70
85
2500
90
100
3000
100
110
4000
135
150
5000
140
150
7000
160
165
6 .4 .14 Checking the Light Arc Stabilizing Magnet
A magnet stabilizes the arc between cathode and anode. An even well adjusted light
arc provides a good optical efficiency and increase the life of the xenon lamp.
DANGER
S
An adjustment can only be carried out by service personnel.
S
An adjustment can only be carried out when xenon lamp is on. Therefore this
adjustment requires special protective equipment.
S
Adjustment must be carried out with a special welders’ mask and suitable protective
equipment.