ZDV3318 - Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Ceiling (from bottom of fireplace) 60 inches/150 cm
Top (from standoffs)
0 inches/0 mm
Louvered Unit
Top of 90 degree bend in Minimum
Enclosure of 37 3/4 to 40 inches 3 1/4 inches/140 mm / All Vent Systems
Enclosure over 40 inches
2 1/2 inches/38mm/All Vent Systems
CVCK Unit (non louvered)
Top of 90 degree bend in Minimum
Enclosure of 40.5inches to 43 inches
5 inches/38 mm / All Vent Systems
Enclosure over 43inches 2 1/2 inches/38mm All vent
Systems
Top of Horizontal Pipe
1 1/2 inches/38 mm / All Vent Systems
Side & Bottom of Horizontal Pipe 1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct
Temp
Systems
(NOTE -Floor) if installing the
appliance directly on
carpeting or other combustible
materials other than wood
flooring, the appliance shall be
installed on a metal or wood
panel, the full width and depth
of the appliance. Carpet may
extend 1 inch above the floor
of appliance.
For units with CVCK (Clear
View Circulating Kit) see
framing with CVCK to
establish floor heights
17
Summary of Contents for ZDV3318 Series
Page 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31 ...
Page 35: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 35 ...
Page 36: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 36 ...
Page 43: ...Proflame 2 Remote Control 43 ...
Page 45: ...45 ...