Burner System Maintenance
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This
operation should be performed by your dealer or a qualified technician.
-CAUTION-
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to
the appliance. Allow the appliance to cool to room temperature. Note that the pilot assembly may be hot in an
intermittent or standing-pilot system
—even if the main burner was never on. Exercise caution when working within the
area.
-ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN-
Monthly Flame Inspection
It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems
with the burner tube. The pilot flame should also be inspected monthly to ensure proper operation.
Flame should appear similar to the above picture.
Conversion Kit Instructions
– PART A
Models: FDV350N, FDV350NE2, FDV350LP, FDV350LPE2
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass
Nipple
Air
Shutter
Hi/Lo
Regulator
350DV-CKLP
Propane
Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#50
1000-253
Closed
Fully
Open
1001-P202SI
(0.907.202)
350DV -CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#32
1000-253
Closed
5/16
”
1001-P201SI
(0.907.201)
350DV -CKLPI
Propane
Conversion
-Proflame 1-
1001-P168SI
#35 (977.168)
#50
1000-253
Closed
Fully
Open
1002-P014SI
(0.907.014)
350DV -CKNGI
NG Conversion
-Proflame 1-
1001-P166SI
#62 (977.166)
#32
1000-253
Closed
5/16
”
1002-P016SI
(0.907.016)
350DV
–CKLPI2
Propane
Conversion
-Proflame 2-
1001-P168SI
#35 (977.168)
#50
1000-253
Closed
Fully
Open
1002-P012SI
350DV
–CKNGI2
NG Conversion
-Proflame 2-
1001-P166SI
#62 (977.166)
#32
1000-253
Closed
5/16
”
1002-P013SI
16