background image

 

10

PART V    DISPLAY PANEL FUNCTION DESCRIPTION

OPERATION 

1. Function description of control panel 

a.

 The temperature display will show the average 

temperature inside the unit while under normal conditions. The 
temperature is displayed in Celsius. 

b.

Door status indicator 
When the door opened, the light is on; when the door is closed, the 
light is off. 

c. Fault indicator light: When the product runs normally, the indicator 

light is off; The indicator light is on for operation abnormality. 

d.

 is the printing key. 

The system can keep the data for 7 days to print. Press the print key 
to print the temperature at any time. 

e.

 is the down key. 

In the parameter setting mode, this will move to the previous 
parameter or reduce the parameter value.  
When setting the set temperature, the temperature is reduced when 
pressed. 

f.

 is the up key. 

In the parameter setting mode, you can move to the next parameter, 
or increase the parameter value. For example, when setting the set 
temperature, this will increase the temperature. When setting 
parameters, the up button will increase the amount of each 
parameter. In normal state, data can be imported by pressing the up 
key for 3 seconds. 

g.

  is the set / mute key. Press this for the inside temperature. 

After 5 seconds, the normal display is restored.  

While the unit is unlocked, press 

 for 3 seconds to enter the 

unit’s menu.  
When the alarm is sounding (including the cabinet high temperature 

alarm, the door open alarm, the sensor fault alarm, etc.), press  

 

and the buzzer will stop. The display will show the temperature for 5 
seconds before returning to normal display.  

While the unit is unlocked, you can use 

 as the settings key. 

In the unlocked state, when setting parameter mode, press this key 
to display the parameter and parameter name. If the press time is 
longer than 3 seconds, the settings will be saved and the display will 
return to the normal interface. 

h. USB data export. 

Automatic export: 

when the USB disk is connected to the USB 

interface, the unit will buzz once, display "on", and the PDF files are 
generated for the current month and the last month. After the data 
transmission is completed, the unit will buzz once again, display 
"end", and then will return to normal display after 6 seconds 

Manually export: 

once the USB disk is inserted, press the 

 for 

3 seconds. The display will show “d01” and you can press up or 
down to select from d01-d012: previous one month to previous 

twelve months. Select the number of months then press 

 to 

confirm the data you want downloaded.  
 

Note: 

when the digital display flickers "LoF", the recorder has not 

started; press 

 

 at the same time, the "LoF" will disappear 

after 3 seconds ,the buzzer will sound once, and the recorder will 
start.

Summary of Contents for MLD270

Page 1: ...ORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Applicable Models MLF90 MLF270 MLD90 MLD270 MLF270 Biomedical Freezer MLD270 Ultra Low Temperature Medical Freezer MLF90 Biom...

Page 2: ...2...

Page 3: ...t be held responsible for any adverse consequences However the user can apply for verification of third party accessories from KingsBottle before use You should inspect and maintain the device accordi...

Page 4: ...the unit do not push the power line up against the wall or other furnishings Leave room for the compressor and heat source as well Use the dedicated power supply according to the instructions on the...

Page 5: ...items that are not suitable for low temperature settings During usage the temperature inside the unit is very low Do not touch the interior surface or any objects inside without protective gear Always...

Page 6: ...the displayed temperature and the actual temperature in the center of the unit at first The center temperature will gradually approach the displayed temperature To clean the interior surface use luke...

Page 7: ...nnected to circuit protection facilities Check the working voltage of the place before starting the freezer A voltage stabilizer is suggested to be used at the place where the voltage is not stable Ma...

Page 8: ...of refrigeration there is a little difference between the actual temperature displayed on the controller and the set temperature This is a normal phenomenon Biomedical freezers are storage devices do...

Page 9: ...e and composition the product consists of a box a glass door structure a refrigeration system and a control system Scope of application This product is suitable for hospitals pharmacies epidemic preve...

Page 10: ...e normal display is restored While the unit is unlocked press for 3 seconds to enter the unit s menu When the alarm is sounding including the cabinet high temperature alarm the door open alarm the sen...

Page 11: ...t is unlocked at this time After unlocking press for 3 seconds the digital display will show the parameter code PS1 enter the desired parameters Use to adjust Display PS1 b1 b2 Set H L n y r S F Pt tH...

Page 12: ...etting 4 H 0 0 10 0 5 0 High temperature alarm set value H H 0 when the alarm is cancelled When the temperature is too high the high temperature alarm shows H1 5 L 0 0 10 0 5 0 Low temperature alarm s...

Page 13: ...ther 1 3 capacity When adding items do not block access to other items stored in the unit Let the cooling process happen for as long as possible before opening the door This will cause the temperature...

Page 14: ...freezer should be cleaned and maintained For the sake of safety first unplug the unit Then wipe the inner and outer surfaces of the freezer with a soft cloth CAUTION DO NOT sprinkle water on the surf...

Page 15: ...hard and deformed Maintenance method Blow the deformed part of the hot seal with a blower to soften it and then close and compress it after the door seal becomes soft Alarm flashing buzzing If you jus...

Page 16: ...e to the negative pole c Remove the two screws from the battery plate with screwdriver then remove the battery d New replaced battery model BT 12M4 0AC 12V4 0AH e The replacement battery is recyclable...

Page 17: ...Defrost Mode Manual Manual Manual Manual Refrigerant R600a R290 R600a R290 Insulation Thickness mm 100 100 100 100 Construction External Material Powder coated material Powder coated material Powder...

Page 18: ...ue to such things as an accident misuse abuse mishandling neglect unauthorized repair or any other cause beyond the control of the seller whether similar or dissimilar to the foregoing Purchaser under...

Reviews: