Kinghome KW09HQ2B8AI Instruction Manual Download Page 1

AIR CONDIT

I

ONER

KW09HQ3B8AI

KW09HQ3B8DI

              KW18HQ3B8DI

KW24HQ3B8DI

KW09HQ2B8AI

KW09HQ2B8DI

KW12HQ2B8DI

KW18HQ2B8DI

:

L

E

D

O

M

 

K

  

  

  

  

  

  

  

K

  

  

  

  

  

  

  

K

INSTRUCTION

 

MANUAL

Summary of Contents for KW09HQ2B8AI

Page 1: ...AIR CONDITIONER KW09HQ3B8AI KW09HQ3B8DI KW18HQ3B8DI KW24HQ3B8DI KW09HQ2B8AI KW09HQ2B8DI KW12HQ2B8DI KW18HQ2B8DI L E D O M K K K INSTRUCTION MANUAL...

Page 2: ......

Page 3: ...for installation 28 Selection of installation location 28 Requirements for electric connection 29 Installation Installation of indoor unit 30 Check after installation 35 Test and operation Test operat...

Page 4: ...jury or property loss is caused by the following reasons Indicates a hazardous situation that if not avoided will result in death or serious injury Indicates a hazardous situation that if not avoided...

Page 5: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 6: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Page 7: ...e neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please Air Conditioner should be p...

Page 8: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Page 9: ...her must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be 5...

Page 10: ...ns FCC STATEMENT accordance with the instructions may cause harmful harmful interference in a residential installation This undesired operation frequency energy and if not installed and used in Howeve...

Page 11: ...h Industry Canada licence This equipment complies with FCC s and IC s RF radiation exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must be installed a...

Page 12: ...nce de 20 cm s pare l appareil l exception du combin des utilisateurs avec ceux ci Les installateurs doivent s assurer qu une 8 Working temperature range Indoor side DB WB C F Outdoor side DB WB C F M...

Page 13: ...nt from above graphics please refer to actual products panel aux button horizontal louver air outlet NOTICE Actual product may be different from above graphics please refer to actual products remote c...

Page 14: ...ome models For some models For some models For some models indicator heating temp indicator cooling indicator power indicator receiver window drying display For some models heating indicator temp indi...

Page 15: ...Set temperature Set time 8 heating function TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Indoor ambient temp Set temp Outdoor ambient temp Clock Sleep mode Heat mo...

Page 16: ...some models Introduction for buttons on remote controller Note After putting through the power the air conditioner will give out a sound Operation indicator is ON red indicator the colour is differen...

Page 17: ...blowed after the unit is stopped to avoid mould Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fan will continue running for a few minutes at low speed In th...

Page 18: ...t turbo function and icon will disappear button 6 Press or button once increase or decrease set temperature 1 1 F Holding or button 2s later set temperature on remote controller will change quickly On...

Page 19: ...again to turn on display light icon is displayed Introduction for buttons on remote controller ller will quit setting status Operation for TIMER ON TIMER OFF is the same 12 TIMER ON TIMER OFF button...

Page 20: ...ton can set the time for timer off After pressing this button icon disappears and the word OFF on remote controller blinks Press or button to adjust TIMER OFF setting After each pressing or button TIM...

Page 21: ...rt I FEEL function and will be displayed on the remote controller After this function is set the remote controller will send the detected ambient temperature to the controller and the unit will automa...

Page 22: ...two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall NOTICE During o...

Page 23: ...ommended to use a soft dry cloth or wet cloth to wipe it NOTICE Do not wash the air conditioner with water to avoid electric shock Turn off the air conditioner and disconnect the power before cleaning...

Page 24: ...to Clean and maintenance panel cover tightly operation environment clean frequency can be increased WARNING the water below 45 to clean it and then put it in a shady and cool place to dry 20 Open pane...

Page 25: ...nage pipe is damaged 1 Disconnect power supply Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air...

Page 26: ...8m Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Ch...

Page 27: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Page 28: ...ess devices etc Disconnect power put back power and then turn on the unit again Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing in...

Page 29: ...g the unit If not please It can be eliminated after restarting the unit If not please F0 Note service Malfunction analysis When below phenomenon occurs please turn off air conditioner and discon for s...

Page 30: ...26 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm Space to the wall Space to the wall At least 15cm...

Page 31: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Page 32: ...end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for installation Don t us...

Page 33: ...er to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with nation...

Page 34: ...on of indoor unit Step one choosing installation location Step two install wall mounting frame rm it with the client 1 plastic expansion particles in the holes 1 Step three open piping hole 2 Choose t...

Page 35: ...with torque wrench cut off the hole When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case left right 1 The pipe can be led out in the direction...

Page 36: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Page 37: ...ak must be installed in the line The circuit break should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the w...

Page 38: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom connection pipe drain hose band indoor power cord Step nine hang the...

Page 39: ...amaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are removed...

Page 40: ...t according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refri...

Page 41: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Page 42: ...ng pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander No...

Page 43: ......

Page 44: ...66129925452...