background image

 

 

 

 

 

 

 

 

 

 

 

 

1/4 

                                                                                 

Installation, Operation & Maintenance Instruction 

(3 PC Body, Clamp / Butt Weld Ends, Sanitary Valve) 

1. Scope:

 This instruction applies to 3-PC Body, Full Port Sanitary Valve, 400WOG (PN25); Clamp 

Ends and Butt weld Ends;    KV-09C/I, KV-091/I, KV-L9C/I, KV-L91/I according to ISO 2852

and 

KV-09C/B, KV-091/B, KV-L9C/B, KV- L91/B according to BS 4825 & BPE. KV-L9C/I

KV-L91/I 

and KV-L9C/B

KV-L91/B designed according to ISO 5211 mounting pad can be fixed with 

actuator directly.

 

 

2.

 

Warning (Restrictions on Use) 

a.

 

Temperature and Pressure Limit 

y

 

The normal maximum operating pressure at maximum or minimum operating temperature is 

shown on nameplate. 

y

 

The operating temperature is within

29

0

C to 200

0

C(if shell is WCB),or 

40

0

C to 200

0

C(if 

shell is stainless steel) for PTFE or RTFE seat and sealing. Other seat and sealing operating 

temperature shall be checked with KI Industries. 

y

 

The nominal pressure (PN) rating describes maximum working pressure in cold operating 

temperature (e.g. PN25 describes maximum working pressure 25 bar at 

39

0

C

40

0

C). 

b. Fluid limited 

      Since this valve is with soft seat, it is not suitable to granules liquor fluid or solidification fluid, 

such as syrup. 

c. No throttling operation 

y

 

Don’t leave the ball partly open where the pressure drop and/or flow rate damage to the valve 

seats and/or ball. 

 

3.

 

Installation  

a. 

Remove the rubber protective cover on clamp or butt welding ends, and clean or flush the valve 

in fully open position(steam sterilization is allowed). 

b. Prior to mounting, flush and clean the pipeline and valve to remove all accumulated extraneous 

maters. 

c. Installation of Clamp ends Ball Valves 

  1)

 Before connecting pipes with valves, should seal the connecting position with seal rings 

according to standards ISO 2852 

2) Should use quick clamps connect and fix the pipes and valves 

d. Installation of Butt welding ball valves. 

    1) Keep valves in open position. lengthen butt welding ends can be welded directly: do 

intermittent welding in four points of both butt welding ends.   

    2) if the butt welding ends is not lengthen, dismount cap bolts, but keep one bolts whose nut 

should be loosen, and then the valve rotating freely.   

Summary of Contents for KV-091/I

Page 1: ...N25 describes maximum working pressure 25 bar at 390 C 400 C b Fluid limited Since this valve is with soft seat it is not suitable to granules liquor fluid or solidification fluid such as syrup c No throttling operation y Don t leave the ball partly open where the pressure drop and or flow rate damage to the valve seats and or ball 3 Installation a Remove the rubber protective cover on clamp or bu...

Page 2: ...n c When the handle if used and or stem flats or groove are in line with the pipe the valve is open d Operating torque requirements will vary depending on the length of time between cycles media in the system line pressure and type of valve seat The figures in the following table C are based on PTFE seats with clean water as the media Table A Torque of Stem Table B Lock Torque of Stem Nut 5 Mainte...

Page 3: ...ve any hazardous material from the valve body yMake sue ball valve 3 is in close position Dismantle body cap bolts but keep one whose nut is loosen the valve will rotate freely yTake out body gasket 17 and seat 4 Examine the ball carefully and any scratch should exchange yWhen stem packing need exchange please dismantle according the following order handle nut handle 16 or driving device stop lock...

Page 4: ...able B stipulated torque figure y If possible do pressure test before placing it back to line for service Table C Lock Torque of Flange Connecting Bolts SS B8 SS B8 MALT S Unit IN LB N M MALT S Unit IN LB N M 1 4 20UNC M6 70 7 9 5 8 11UNC 800 90 5 5 16 18UNC M 100 11 3 3 4 10UNC 1400 158 4 3 8 16UNC 160 18 1 7 8 9UNC M22 2250 254 6 7 16 14UNC M 280 31 7 1 8UNC M24 3250 367 7 1 2 13UNC M1 400 45 3 ...