_________________________________________________________________________________________
Page 8 of 11
Ver 1.7 File No.:RTU5034103
A Professional GSM 3G M2M products manufacturer
and automation solution provider, since 2005.
www.4G-RTU.com [email protected]
5.2.2 Inquiry batch users number
E.g.:
1234AL002#050#
to inquiry the authorized numbers from the 2
nd
to the 50
th
,RTU5034 return several
SMS with the numbers list(10 numbers on each SMS).
5.2.3 Delete the Authorized User’s Number
(
or you can overwrite this position with another number).
E.g.:
1234A002##
to delete the 2
nd
authorized number.
5.3 Relay Control setting
5.3.1 Allow all numbers can call in to control:
5.3.2 Allow only the authorized numbers can call in to control(Caller-ID for security, default):
5.3.3 How long time the relay keep close(ON) after phone call in (unit: second)
close time=000~999. Unit: Second
close time=000: relay close 0.5 second then open (use the relay as Latch).
close time=999: relay will always keep close(ON) after call in until the next call in.
E.g.:
1234GOT030#
to set relay close 30 seconds(ON) and then open(OFF) after call in.
5.3.4 Who will receive the confirmation SMS when the relay is ON/OFF
for relay ON,
for relay OFF.
ab:
the ID code of the 1
st
number(a) and the caller number(b), =0 means disable, =1 means enable.
content:
confirmation SMS content.
ID code
RTU5034 send notify SMS to
a
b
The 1
st
number
Caller number
0
0
0
1
√
1
0
√
1
1
√
√
E.g.:
1234GON11#Door Open#
The 1
st
number & the caller number receive confirmation SMS when relay is ON(door opened).
E.g.:
1234GOFF00#Door Close#
The 1
st
number & the caller number will not receive confirmation SMS when relay is OFF(door closed)..
5.3.5 No need confirmation SMS when the relay is ON/OFF.
pwdAL
serial number start
#
serial number end
#
pwdA
serial number
##
pwdALL#
pwdAUT#
pwdGOT
close time
#
pwdG
OFF
ab#
content
#
pwdG
ON
ab#
content
#