background image

1. Setup Language
2. Setup Time
3. Setup Alert Number
4. Temperature Alert
5. Armed Alert by Sound

6. Armed Delay Time

7. Armed Alert Tel 1
8. Alarm Sound Time
9. Alarm Delay Time

Armed Delay Time

30

Arm Delay Time

Default: 30 seconds.
Optional: 0~99 seconds.

1. Setup Language
2. Setup Time
3. Setup Alert Number
4. Temperature Alert
5. Armed Alert by Sound
6. Armed Delay Time

7. Armed Alert Tel 1

8. Alarm Sound Time
9. Alarm Delay Time

Armed Alert Tel 1

No

Yes

Arm Notify SMS

No:  The 1st receiver will not get 
notify SMS when system Armed.

 The 1st receiver will get 

Yes:
notify SMS when system Armed.

Alarm Sound Time

1. Setup Language
2. Setup Time
3. Setup Alert Number
4. Temperature Alert
5. Armed Alert by Sound
6. Armed Delay Time
7. Armed Alert Tel 1
8. Alarm Sound Time

9. Alarm Delay Time

Alarm Delay Time

1. Setup Language
2. Setup Time
3. Setup Alert Number
4. Temperature Alert
5. Armed Alert by Sound
6. Armed Delay Time
7. Armed Alert Tel 1

8. Alarm Sound Time

9. Alarm Delay Time

Alarm Sound Time

180

Default: 180 seconds.

Alarm Delay Time

20

Default: 20 seconds.
Optional: 0~999 seconds.

11

12

Summary of Contents for K9

Page 1: ...switch channel for remote control door access works with WS1 WS2 Just simply dial in to the K9 change the status to Arm Stay Disarm by missed call or create two way talk automatically Monitoring zone for take care of elderly daily life activities Temperature monitoring alarm Wireless sensors battery low power alarm SMS Backup rechargeable battery inside AC power lost alert available Audible alarm ...

Page 2: ...tected by the 5th zone s PIR Door sensor during the monitoring time period For example install one wireless door sensor at your Dad s bed room setting the monitoring time period as 05 30 09 00 am if he didn t get up didn t open his door during that time system sends alert SMS to the you says Monitor Zone Alarm you can edit this SMS text for sure You will receive SMS text only for this event no cal...

Page 3: ...sensors in Inner zones which disarmed so that users can move freely at home Disarm Button Press Disarm button and 4 digits password default 1234 and press to disarm the system after two beeps SOS Button Press the SOS button more than 2 seconds to make SOS alarm Call Button Dial phone number and then press Call button to start talk or answer phone call in You can also press the Call button to end t...

Page 4: ...ht 100 240V AC Alarm Output 1A 2B 5 Mount Socket Tamper Switch Terminal cover Speaker Mounting Bracket Screw hole Install the bracket on the wall by using screws after wiring connection and power on plug the socket to the bracket tightly make the tamper switch close When plug out the socket tamper switch will make alarm Wiring Connections Bottom View 6 ...

Page 5: ...Italiano 6 Dansk 7 Cestina 8 Francais 9 Bahasa 1 Setup Language 2 Setup Time 3 Setup Alert Number 4 Temperature Alert 5 Armed Alert by Sound 6 Armed Delay Time 7 Armed Alert Tel 1 8 Alarm Sound Time 9 Alarm Delay Time Select Language Setup Date Time Month Day Year Setup Time 23 15 10 33 26 06 Reset Open the SIM Card cover press and hold the Reset button Switch ON After 5 seconds release the Reset ...

Page 6: ...alarm 3 receivecallonlywhenalarm Functioncode2 whenthisnumbercalltosystem 1 systemchangesstatusfromAwayArmtoStayArm 2 systemanswersthecallautomatically 3 systemneedstopressCallbuttontoanswerthecallin 1 High 99 2 Low 99 1 Setup Language 2 Setup Time 3 Setup Alert Number 4 Temperature Alert 5 Armed Alert by Sound 6 Armed Delay Time 7 Armed Alert Tel 1 8 Alarm Sound Time 9 Alarm Delay Time Armed Aler...

Page 7: ...el 1 No Yes Arm Notify SMS No The 1st receiver will not get notify SMS when system Armed The 1st receiver will get Yes notify SMS when system Armed Alarm Sound Time 1 Setup Language 2 Setup Time 3 Setup Alert Number 4 Temperature Alert 5 Armed Alert by Sound 6 Armed Delay Time 7 Armed Alert Tel 1 8 Alarm Sound Time 9 Alarm Delay Time Alarm Delay Time 1 Setup Language 2 Setup Time 3 Setup Alert Num...

Page 8: ...6 24Hr Silent Zone 7 Armed 8 Stay 9 Not Use 10 Door Bell Edit Wired Zone 1 2 1 Edit Remote 2 Edit Wired Zones 3 Edit RF Detector 2 Tamper Switch Type 24Hr Sound Zone Name Tamper Switch 3 Wired Zone 1 Input NO Type Not Use Name Wired Zone 1Alarm 4 Wired Zone 2 Input NO Type Not Use Name Wired Zone 2 Alarm st The 1 zone the SOS button on the keypad the tamper switch on back side nd The 2 zone the Wi...

Page 9: ... SMS and dial only no audible alarm sound Used for Main gate or lobby Intrusion protection outside of the house Intrusion protection inside the house Windows or rear gate Smoke fire Gas Water CO leakage detection Emergency help SOS alarm Press to Arm the system no need remote control Press to Stay Arm no need remote control Disabled the zone Door bell Sensors Door sensors PIR sensors Door PIR Been...

Page 10: ... definition often it is tripped With this function you can bypass an upstairs window so that you can leave it open during the day without having to worry about it setting off your alarm For example you want to be able to open and close a specific window during the night while your system is armed You want to bypass a certain motion sensor so that a person or pet can move through an area without cr...

Page 11: ...you should reject the system s recall and open your door at same time This setting will help you to open the garage or main gate when leaving home by a single phone call 2 Interlock Stay by call you should call the system twice within 30 seconds to change the system to Stay Home Arm mode and open your door at same time This setting will help you to open the garage or main gate when back home 1 Arm...

Page 12: ...on the system coding 1 is the default for wireless siren optional Panel s SIM Card No Enter the Alarm panel s SIM Card number for gain date time from mobile network Alarm system will get mobile operator s date time according to the phone number LCD will correct and display the real date time after few minutes when setting done If system can t get date time automatically please try to add or remove...

Page 13: ...ce on command list just for reading purpose Function Arm Disarm Alarm sound ON Alarm sound OFF Inquiry status Modify password Add alert number alarm receiver Inquiry alert number Delete alert number SMS Commands 1234AA 1234BB 1234CC 1234DD 1234EE 1234 new password P 1234 position 1 9 A function code 1 1 3 function code 2 1 3 phone number 1234A 1234position 1 9 A Description Example Away Arm system...

Page 14: ...rt content Modify zone function Alarm sound time Alarm delay time Arm delay time Arm notify SMS Arm notify SMS disable Monitor on site voice 1234 H 1234 J 1234 K 1234 zone number B 1234 zone number D 01 99 function code 0 9 1234 sound time E 001 999 1234 alarm delay F time 000 999 1234 arm delay G time 00 99 Setting Operation by SMS commands 1234GT030 Default 1 second To set the Wireless access co...

Page 15: ...ss zone 11 alarm Wireless zone 12 alarm Wireless zone 13 alarm Wireless zone 14 alarm Wireless zone 15 alarm Wireless zone 16 alarm Wireless zone 16 alarm Wireless zone 17 alarm Wireless zone 99 alarm Wirelesssensor sbattery low power alert AC Power Goes off AC Power Goes on Remote Key SOS Help SOS Help Tamper Switch Alarm Wired Zone 3 Alarm Wired Zone 4 Alarm Monitor Zone Alarm Entrance Alarm Zon...

Page 16: ...u should call the system twice within 30 seconds to change the status to Stay Home Arm mode and open your door at same time This setting will help you to open the garage or main gate when back home 3 Disabled the remote access control interlock function Works with the wireless switch WS1 optional you can remote open your electronic lock or other devices by pressing or control by incoming phone cal...

Page 17: ...ore and then ask the engineer to check the GSM Module socket and the GSM Module connection 3 Please change another location to install the alarm panel Backup battery low voltage Auto Restart Plug the AC DC Power adapter Solution PIR Motion sensor installation incorrect False Alarm Please install the PIR sensor according to the user manual carefully Solution No SMS Call when alarm No action when yo...

Reviews: