Warning :

Read instructions thoroughly before using digital thermometer.

Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children to use this device

without parental supervision.

Do not use thermometer in ear.  Designed use is for oral, rectal, and armpit (axilla) readings only.

Do not place thermometer battery near extreme heat as it may explode.

Remove battery from the device when not in operation for a long time.

The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the interpretation of

results. Self-diagnosis may lead to the worsening of existing disease conditions.

Do not attempt measurements when the thermometer is wet as inaccurate readings may result.

Do not bite the thermometer. Doing so may lead to breakage and/or injury.

Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.

After each use, disinfect the thermometer especially in case the device is used by more than one person.

Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is present.

Failure to do so may lead to injury.

Do not use thermometer orally after being used rectally.

For children who are two years old or younger, please do not use the devices orally.

If the unit has been stored at temperatures over 41°F~104°F (5°C~40°C), leave it in 41°F~104°F (5°C~40°C)

ambient temperature for about 15 minutes before using it.

Indications For Use

The digital thermometers are intended to measure the human body temperature in regular mode orally, rectally or
under the arm. And the devices are reusable for clinical or home use on people of all ages, including children under 8
years old with adult supervision.

Battery Replacement

1. Replace battery when "      " appears in the lower right corner of LCD display.
2. Pull battery cover off as shown in Figure 3.
3. Gently pull out plastic circuit board with battery chamber approximately 1 cm (slightly less than 1/2".) 
    (See Figure 4) 
4. Use pointed object such as a pen to remove old battery. Discard battery lawfully. Replace with new 1.5V DC button
    type LR41 or SR41, UCC392, or equivalent. Be sure battery is installed with " 

+

 " polarity facing up. (See Figure 5)

5. Slide battery chamber back into place and attach cover.

Troubleshooting

Contents

1 Thermometer, 1 Owner’s Manual, 1 Storage Case

Product Illustration

Figure 1

Please Read Carefully Before Using

This digital thermometer provides a quick and highly accurate reading of an individual's body temperature. To better
understand its functions and to provide years of dependable results, please read all instructions first.
This appliance conforms to the following standards:
EN 12470-3 Clinical thermometers —Part 3: Performance of compact electrical thermometers (non-predictive and
predictive) with maximum device,
ISO 80601-2-56 Medical electrical equipment —Part 2-56:Particular requirements for basic safety and essential
performance of clinical thermometers for body temperature measurement,
EN 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and essential
performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems
used in the home healthcare environment and complies with the requirements of EN 60601-1-2(EMC),
IEC/EN 60601-1(Safety) standards. And the manufacturer is ISO 13485 certified.

Cleaning And Disinfection

1) Immerse the thermometer probe in distilled water for at least 1 minute;
2) Using a clean, soft cloth to wipe the thermometer down to remove any residue;
3) Repeat step 1 and 2 for three times until no soil is seen with visual inspection after cleaning;
4) For thoroughly clean and disinfection, please use method A or B: Method A(High level disinfection): immerse the
    thermometer probe in 0.55% OPA(O-Phthaldehyde), such as CIDEX OPA, for at least 12 minutes under temperature
    at 20°C ; Method B(Low level disinfection): Using a clean soft cloth dipped in 70% medical alcohol, wipe the probe
    3 times, at least one minute for each time.
5) Repeat step 1 to 3 to remove OPA residuals;
Note 1: Rectal use is not recommended for home use as OPA will not be readily available outside of a hospital. If
rectal measurement is necessary, we strongly recommend high level disinfection.
Note 2: Please operate according to the manual of OPA for reference.
To prevent damage to the thermometer please note and observe the following:
- Do not use benzene, paint thinner, gasoline or other strong solvents to clean the thermometer.
- Do not attempt to disinfect the sensing probe (tip) of the thermometer by immersing in alcohol, OPA or in hot water
  (water over 122°F (50°C)) for long time.
- Do not use ultrasonic washing to clean the thermometer.

Calibration

The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to the use
instruction, periodic readjustment is not required. However, we recommend checking calibration every two years or
whenever clinical accuracy of the thermometer is in question. Turn on the thermometer and insert into the water bath
and then check the laboratory accuracy of thermometer. Please send the complete device to the dealers or
manufacturer.
The above recommendations do not supersede the legal requirements. The user must always comply with legal
requirements for the control of the measurement, functionality, and accuracy of the device which are required by the
scope of relevant laws, directives or ordinances where the device is used. 

Limited Warranty

The thermometer is guaranteed for one year from the date of purchase. If the thermometer does not function properly
due to defective components or poor workmanship, we will repair or replace it free of charge. All components are
covered by this warranty excluding the battery. The warranty does not cover damages to your thermometer due to
improper handling. To obtain warranty service, an original or copy of the sales receipt from the original retailer is
required. 

Directions

Precaution

Symbol Explanation

°C/°F Switchable

Specifications

Battery Cover

Probe

LCD

ON/OFF Button

The performance of the device may be degraded should one or more of the following occur:
   Operation outside the manufacturer’s stated temperature and humidity range.
   Storage outside the manufacturer’s stated temperature and humidity range.
   Mechanical shock (for example, drop test)or degraded sensor.
   Patient temperature is below ambient temperature.
Portable and mobile RF communications can affect the device. The device needs special pre-

cautions regarding EMC according to the EMC information provided in the accompany documents.
Keep thermometer away from Magnetic Resonance equipment.

*

   -
   -
   -
   -

*
*

Type BF Applied Part

Direct Current

European Authorized Representative

Read the instructions (actual symbol
colours are white on a blue background)

Storage and Transportation Temperature
Limit: -20°C~55°C (-4°F~131°F)

Manufacturer

Manufacture date

55°C

-20°C

Type:

Digital Thermometer (Not Predictive)

Measure Range:

32.0°C ~ 42.9°C (90.0°F ~ 109.9°F) (°C/°F chosen by manufacturer)

Accuracy:

±0.1°C (±0.2°F) during 35.5°C ~ 42.0°C (95.9°F ~ 107.6°F) at 18°C ~ 28°C

(64.4°F ~ 82.4°F) ambient operating range ±0.2°C (±0.4°F) for other measuring

and ambient operating range

Operating mode:

Direct Mode

Display:

Liquid crystal display, 3 1/2 digits

Memory:

For storing the last measured value

Battery:

One 1.5V DC. button battery (size LR41 or SR41, UCC 392)

Battery life:

Approx. 200hours of continuous operation or 1 year with 3 measurements per day

Dimension:

13.1cm x 2.0cm x 1.2cm (L x W x H)

Weight:

Approx. 10 grams including battery

Expected service life:

Three years

Ambient operating range:

Temperature: 5°C ~ 40°C (41°F ~ 104°F)

Relative humidity: 15% ~ 95%RH

Atmospheric Pressure : 700hPa ~ 1060hPa

Storage and transportation

condition:

Temperature: -20°C ~ 55°C (-4°F ~ 131°F)

Relative humidity: 15% ~ 95%RH

Atmospheric Pressure : 700hPa ~ 1060hPa

Ingress Protection Rating:

IP 27

Classification:

Type BF

Temperature readings are available in the Celsius or Fahrenheit scale (°C/°F; located in the upper right corner of LCD.)
With the unit off, press and hold the On/Off Button for approximately 2 seconds to change the current setting. 

Figure 2

1. Press the On/Off Button next to LCD display. A tone will sound as the screen shows                , followed by last
    recorded temperature. After showing the self-test temperature, the thermometer is now in the testing mode.
2. Position thermometer in desired location (mouth, rectum, or armpit.)
    a) 

Oral Use:

 Place thermometer under tongue as indicated by "     " position shown in Figure 2.

        Close your mouth and breathe evenly through the nose to prevent the measurement from
        being influenced by inhaled/exhaled air.
    b) 

Rectal Use:

 Lubricate silver probe tip with petroleum jelly for easy insertion. Gently insert

        sensor approximately lcm (less than 1/2 ") into rectum.
    c) 

Armpit Use:

 Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side.

        From a medical viewpoint, this method will always provide inaccurate readings, and
        should not be used if precise measurements are required.
3. The degree sign flashes throughout the testing process. When flashing stops an alarm will beep for approximately
    10 seconds. The measured reading will appear on the LCD simultaneously. The minimum measurement time until
    the signaling tone (beep) must be maintained without exception. The measurement continues even after the buzzer
    notification. So that in order to achieve better body temperature measurement result, recommend to keep the
    probe in mouth and rectum about 2 minutes, or in armpit about 5 minutes regardless of the beep sound and at
    least 30 seconds measurement interval should be maintained. 

 

4. To prolong battery life, press the On/Off Button to turn unit off after testing is complete. If no action is taken, the
    unit will automatically shut off after around 10 minutes.

Error message

Problem

Solution

Temperature taken is

lower than 32.0°C (90.0°F)

Temperature taken is

higher than 42.9°C (109.9°F)

The system is not functioning

properly.

Dead battery: Battery icon is

flashing, can't be measurable.

Turn off, wait one minute and take a new temperature

via close contact and sufficient rest.

Turn off, wait one minute and take a new temperature

via close contact and sufficient rest.

Unload the battery, wait for 1 minute and repower it. If

the message reappears, contact the retailer for service.

Replace the battery.

Figure 3

Figure 4

Figure 5

The product is in compliance with the requirements

of MDD 93/42/EEC, "0197" is the identification

number of notify body.

JOYTECH HEALTHCARE CO. LTD.

No.365, Wuzhou Road, Yuhang Economic Development Zone,

Hangzhou city, 311100 Zhejiang, China

Disposal of this product and used batteries should be carried out

in accordance with the national regulations forthe disposal of

electronic products.

Shanghai International Holding Corp. GmbH (Europe)

Eiffestrasse 80, 20537 Hamburg, Germany

Reviews: