i.
Make sure that the end clamp is set to the correct size for the
module you are using.
ii.
The end clamp should touch both the rail and the module without
tightening
iii.
If it is not the correct height, disassemble the clamp, slide the
teeth into the correct spot and reassemble
b.
Position modules on top of rails in desired position
c.
Insert mid clamps by sliding or lifting edge of module and inserting in a
similar fashion to the end clamps
d.
Slide modules into desired position (ensure squareness) and torque end
and mid clamps to fix in place
Required Maintenance
At 6 months and 12 months after installation and at least once yearly afterwards, check
to ensure that all bolts remain at the proper torque setting.
Appendix 1
– Grounding Guidelines
One grounding lug is required per array. Grounding can be achieved using a Kinetic
Grounding Lug attached to either Hat Rail or the A-Frame.