background image

4.3

Removing the Control Tap from the fire.

4.3.1

Remove the burner assembly as in section 4.1.

4.3.2

Pull the control knob off the control tap spindle.

4.3.3

Loosen and remove the three gas pipe retaining nuts from the control

tap and release the ends of the gas pipes from the control tap body.

Loosen and remove the thermocouple securing nut from the end of the

control tap.

4.3.4

Unscrew the control tap locknut from the front of the control panel and

remove the control tap.

4.3.5

To refit a control tap, reassemble in reverse order noting that the control

tap locates with a flat in the control panel. Carry out a gas tightness

test after re-assembly.

4.4

Removing the Oxy-Pilot Assembly

Note : Because this appliance is fitted with an atmosphere sensing ‘Oxy-

Pilot’ it is not possible to replace the thermocouple separately, because the

thermocouple position is factory set to a tight tolerance. Any replacement of

parts on the pilot requires a complete new pilot assembly.

4.4.1

Remove the burner assembly as in section 4.1

4.4.2

Unscrew and remove the thermocouple retaining nut from the end of the

control tap and disconnect the ignition lead from the pilot electrode.

4.4.3

Unscrew and remove the two pozi-driv screws which secure the pilot

assembly to the burner. Remove the pilot.

4.4.4

Re-assemble in reverse order and carry out a gas tightness test.

25

Note : Prior to replacing the oxypilot on this product due to suspected

failure of the component, please remove all debris that has collected on

the lint guard of the oxypilot itself.

Summary of Contents for Black Magic

Page 1: ...Magic DECORATIVE FUEL EFFECT GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No KRDCD0MN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Page 2: ...stem 9 Section 2 Installation of Fire 2 1 Unpacking the fire 10 2 2 Installing the fire box 10 2 3 Gas tightness and inlet pressure 16 Section 3 Assembling Fuel Bed and Commissioning 3 1 Assembling th...

Page 3: ...fitted Width with trim no spacer 520mm Height with trim no spacer 610mm Depth from mounting face to rear panel without spacer fitted 170mm Efficiency Declaration The efficiency of this appliance has b...

Page 4: ...and Terminals 8 I S 813 1996 Domestic Gas Installation Republic of Ireland In Repuplic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B...

Page 5: ...150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Check that the chimney flue only ser...

Page 6: ...ied out during commissioning of the appliance 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 375 and 440 mm wide and between 550 and 570mm high...

Page 7: ...use in fireplaces fitted with an existing chairbrick without the need for removal of the chairbrick providing the minimum depth of the fireplace exceeds 260mm If the depth is less than 260mm then the...

Page 8: ...n accordance with BS EN 1858 pre cast flues built with directly plastered faces front or rear are not correctly installed as to ensure proper operation with any type of gas fire In some instances of t...

Page 9: ...h the fire is operated The following are important warnings relating to this spillage monitoring system 1 The spillage monitoring system must not be adjusted by the installer 2 The spillage monitoring...

Page 10: ...ook 2 2 INSTALLING THE FIRE BOX Establish which type of flue you are intending to install the fire in to 225 x 225mm 9 inch x 9 inch brick built chimneys 175mm 7 inch diameter lined brick or stone flu...

Page 11: ...ge and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps presen...

Page 12: ...n to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 5a 5b below for suggested concealed pipe layouts Fig 5...

Page 13: ...which in turn will damage the burner and control systems of the product Fig 6 below shows a correctly sealed installation Fig 6 PLEASE NOTE 13 BFM EUROPE LTD WILL NOT BE LIABLE FOR GUARANTEE CLAIMS T...

Page 14: ...round the perimeter of the firebox in a goalpost arrangement to ensure a seal is achieved to the fireplace To fit using the preferred cable method proceed as follows e Mark out and drill 4 off No 14 7...

Page 15: ...nut i Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning screw then secure each nipple with a flat bladed screwdriver See fig 8 below Fig 8 j Evenly tighten th...

Page 16: ...aused to the gas control valve on the fire The other firebox fixing method is as follows In installations where the cable method is not suitable e g loose masonary in rear of fire opening the firebox...

Page 17: ...ol knob for a few seconds to purge the pipe work then press the igniter button The burner should light continue to hold the control knob for a few seconds then turn to the full on position d Check tha...

Page 18: ...t and is not lodged on the burner See fig 10 below Fig 10 b Position the two halves of the front ceramic L H R H on the locating channel in the front ceramic ensuring it is located onto the lip on the...

Page 19: ...hey are evenly spaced Use the recess s in the front ceramic rail as a guide for placement See fig 12 below Fig 12 d Select four of the large coals and arrange behind the front row of coals ensuring th...

Page 20: ...along the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 14 below Fig 14 f Select the two small coals and position to fill the gaps at each end of the...

Page 21: ...e articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working o...

Page 22: ...he pilot position the main burner will go out but the pilot will remain lit g Slightly depress the control knob and turn to the off position the pilot will now be extinguished WARNING If the fire goes...

Page 23: ...ith the fan running on maximum and all interconnecting doors open f After ensuring that the fire is safe to use it should be left on high position to fully warm up During this time a slight odour may...

Page 24: ...location Remove the loose coals from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which secure the burner heat shield and remove i...

Page 25: ...e Oxy Pilot Assembly Note Because this appliance is fitted with an atmosphere sensing Oxy Pilot it is not possible to replace the thermocouple separately because the thermocouple position is factory s...

Page 26: ......

Page 27: ......

Page 28: ...et B 56340 L H Fibre Board B 56200 R H Fibre Board B 56210 Upper Rear Fibre Board B 56230 Lower Rear Fibre Board B 56220 Piezo Igniter B 1320 Ignition Wire B 39030 Manual Gas Valve NG B 102880 Due to...

Reviews: