![Kinco CV100 Series Manual Download Page 60](http://html1.mh-extra.com/html/kinco/cv100-series/cv100-series_manual_1967653060.webp)
57
selector
C2.24 Step 12 operating time
0.0~6500.0
【
20.0
】
C2.25 Step 13 setting mode
selector
Same as C2.01
C2.26 Step 13 operating time
0.0~6500.0
【
20.0
】
C2.27 Step 14 setting mode
selector
Same as C2.01
C2.28 Step 14 operating time
0.0~6500.0
【
20.0
】
C2.29 Step 15 setting mode
selector
Same as C2.01
C2.30 Step 15 operating time
0.0~6500.0
【
20.0
】
C2.01~C2.30 are used to set the operating frequency,direction,
Acc/Dec time and operating time for PLC function.Here takes
C2.01 as example,as shown in Fig.6-52.
Fig.6-52 PLC steps setting
The unit’s place of LED:
0:Multiple frequency N(N:corresponding to current step)
The frequency of current step depends on the multiple
frequency N.About the details of multiple frequency
setting,please refer to Group C0.
1:Defined by A0.02.
Use A0.02 to set the frequency of current step.
2.Multiple closed loop reference N(N:corresponding to
current step)
The frequency of current step depends on the multiple
closed loop reference N.About multiple closed loop
setting,please refer to C1.19~C1.33.
3:Defined by C1.01.
PLC runs in process closed loop mode,the closed loop
reference is defined by C1.01.
Ten’s place of LED:
0:Forward
Set the direction of current step as forward
1:Reverse
Set the direction of current step as reverse
2:Defined by operation command
The direction of current step is defined by the operation
command of terminals.
Note:
If the operation direction of current step can not be
confirmed,then it will continue the previous direction.
6.18 Group C3
Swing function is suitable for application like spinning
which requires winding and swing function.Its typical
operation is as shown in Fig.6-53.
Fig.6-53 Swing operation
The process of swing control:Firstly the drive accelerate
to preset swing frequency(Set in C3.02),and wait for
some time(Set in C3.03),then accelerate to centre
frequency,and run cyclic according to the swing
amplitude(C3.04),Jump frequency(C3.05),Swing
cycle(C3.06) and Triangle wave rising time(C3.07),and
then stop in dec time when there is stop command.
C3.00
Swing
function
selector
0~1
【
0
】
0
:
Disable
1
:
Enable
A
B
C
D
0:
Multiple frequency N(N:
1:
corresponding to current step)
2:
Multiple closed-loop reference N
3:
Defined by A0.02cycle
0:
Forward
1:
Reverse
2:
Defined by operation command
0:
Acc/Dec time 1
(N:corresponding to current step)
Defined by C1.01
Acc/Dec time 2
1:
Acc/Dec time 3
2:
Acc/Dec time 4
3: