Kimray BK2800 Programming & Installation Manual Download Page 1

BK2800 Flow Monitor 

Model 2800

Programming & Installation Manual

1

Kimray is an ISO 9001- certified manufacturer. Kimray quality assurance process maintains strict controls of materials

and the certification of parts used in Kimray electronic level switch.

Kimray.com

IM:0021

July 2017

Introduction

The BK2800 Flow Monitor is a state-of-the-art, microprocessor

based flow monitor, designed to provide the user with exceptional

flexibility at a very affordable price. Though designed for use

with Kimray Flow Meters, this display can be used with almost

any flow meter producing a low amplitude AC output or contact

closure signal(s).

This flow monitor is capable of accepting a low-level frequency

input for calculating flow rate and total. These calculations can

then be displayed in the desired units of measurement. All B2800

flow monitors come pre-calibrated, from the factory, if ordered

with a Kimray Flow Meter. If required, however, it can easily be

re-configured in the field. The monitor’s large 8 digit by .75” numeric

liquid crystal display makes extended range viewing practical.

The second 8 digit by .38” alphanumeric display provides for

selectable units viewing in run mode and prompts for variables in

programming mode. Finally, the user can choose between displaying

rate, total, or alternating between both rate and total.

Introduction     

             1

Specifications   

 

2

Programming Mode 

 

2

Additional Input Options  

5

Wiring Diagram          

             6

Troubleshooting  

             7

Installation Drawing                    10

Part Numbering Information       11

Contents

Kimray is an ISO 9001- certified manufacturer. Kimray quality assurance process maintains strict controls of materials

and the certification of parts used in Kimray electronic level switch.

Note

Kimray reserves the right to make any changes or

improvements to the product described in this manual at any

time without notice.

Summary of Contents for BK2800

Page 1: ...All B2800 flow monitors come pre calibrated from the factory if ordered with a Kimray Flow Meter If required however it can easily be re configured in the field The monitor s large 8 digit by 75 nume...

Page 2: ...I III Div 1 Groups C D CE IEC 61326 1 Specifications Operating the Monitor The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode Both the run mode and the program mod...

Page 3: ...orrect flows and totals Note Unless otherwise specified Kimray turbine flow meters are supplied with K factors measured in pulses per gallon PUL GAL which will automatically convert to your desired un...

Page 4: ...the arrow keys to scroll to the desired display mode and press ENTER to save the choice A TEST function is also available in the Display Function sub menu With the test function selected the display a...

Page 5: ...ean fresh battery to insure continued trouble free operation It is recommended that the total be saved to memory before the battery is removed See STORE TOTAL in the programming section of this manual...

Page 6: ...Programming Installation Manual 6 Kimray is an ISO 9001 certified manufacturer Kimray quality assurance process maintains strict controls of materials and the certification of parts used in Kimray ele...

Page 7: ...ty Try disconnecting the pick up from the monitor pig tail This should stop the noise If not then try re orientating the meter to a new location Flow Rate Indicator Bounces This usually indicates a we...

Page 8: ...Programming Installation Manual 8 Kimray is an ISO 9001 certified manufacturer Kimray quality assurance process maintains strict controls of materials and the certification of parts used in Kimray ele...

Page 9: ...next parameter If adjustment is required use the RIGHT arrow key to select the position of the number you wish to change then use the UP arrow key to increment the number Once you have completed this...

Page 10: ...rogramming Installation Manual 10 Kimray is an ISO 9001 certified manufacturer Kimray quality assurance process maintains strict controls of materials and the certification of parts used in Kimray ele...

Page 11: ...only The default is gallons per minute All contents of this publication including illustrations are believed to be reliable And while efforts have been made to ensure their accuracy they are not to be...

Page 12: ...cation including illustrations are believed to be reliable And while efforts have been made to ensure their accuracy they are not to be construed as warranties for guarantees express or implied regard...