background image

If the dataset is in progress:

The Kistock displays            *
The data collector displays 

”Stop YES”

.

Confirm dataset stop by pressing 

OK

 key (to cancel, press 

Select.

“Stop NO”

 is displayed then press 

OK

).

The data collector displays the data transfer progression: 0-100%.

The dataset recorded by the Kistock is stored on the data 
collector.

4.6 Kistock – data collector interface

4.6.1 Download the Kistock data on the data collector

Procedure to download data:

When data are transferred from the Kistock to the data collector, these measurement data are copied. Only the
sending of a new configuration with the data collector or the Kilog 2015 software allows to start an other dataset
(see procedure described page 9).

Device use

7

 REC

If the data collector does not detect any point to download:

The data collector displays 

“No Pts”

 error message.

This message indicates that the dataset did not start already or that 
the first point is not recorded yet.
Check that the dataset started:

If the Kistock is still waiting for dataset to start, it displays           
flashing icon*.

Press the data collector 

OK

 key to start the dataset.

The data collector displays 

“Start Yes”.

Press 

OK

 to confirm (to cancel, press 

Select

., 

“Stop no” 

displays 

then press 

OK

)

If the dataset is finished:

The Kistock displays           *
The data collector displays the data transfer progression: 0-100% 

The dataset recorded by the Kistock is stored on the data 
collector.

1- Plug the data 
collector on the 

Kistock

2- Switch on the 

data collector.

“On” displays.

3-a. Store the dataset on 

the data collector

 END

3-b. “Stop YES”

Stop or continue the 

dataset

3-c. “No Pts”

No points detected

 REC

1- Switch on the data 

collector. “On” is displayed.

2- Display used 

storage capacity

Or wait

5 seconds

3- “On”

Back to home screen.

* only for models with display

Summary of Contents for KNT 320

Page 1: ...KNT 320 data collector Data storage and recovery for KISTOCK 2015 dataloggers...

Page 2: ......

Page 3: ...e capacity 6 4 6 Kistock data collector interface 7 4 6 1 Download the Kistock data on the data collector 7 4 6 2 Reconfigure the Kistock and start an other measurement dataset 8 4 6 3 Summary of func...

Page 4: ...to download and store the recorded data from Kistock 2015 devices in order to download them on a computer The KNT 320 also allows to send a new configuration and start an other measurement dataset wit...

Page 5: ...1 OK key 1 ON OFF Selection key Material Compatible with food industry environment ABS housing Protection IP65 Communication Data collector PC integrated A male USB connector Data collector Kistock f...

Page 6: ...capacity 6 Device use Store the Kistock datasets on the data collector Send a new configuration on the Kistock devices and start an other dataset When the icon appears data transfer is in progress RE...

Page 7: ...he data collector displays No Pts error message This message indicates that the dataset did not start already or that the first point is not recorded yet Check that the dataset started If the Kistock...

Page 8: ...l memory values are recorded until the storage capacity of the device is reached The configuration which is sent depends on the Kistock last configuration Initial configuration Stop type Configuration...

Page 9: ...configuration is sent The Kistock displays flashing icon Device is waiting for start The data collector displays On A new configuration has been sent but the dataset did not start The Kistock is autom...

Page 10: ...wnload The error message No Pts is displayed The dataset did not start already or the first point has not been recorded yet Conf YES is displayed Allows to send a new configuration on the Kistock Star...

Page 11: ...he measurement datasets are displayed and automatically saved in the defined location 4 7 2 Display data collector state delete memory and set date and time Plug the data collector on a USB port of th...

Page 12: ...e Customised proxy indicate the Proxy address then the user name and password Click on Start update to start the device updating The progress of the updating displays in the progression bar A message...

Page 13: ...g auto play window opens Click on Open folder to view files The folders are organised according to the serial number of the devices used The sub folders are settled by dates of the measurement dataset...

Page 14: ...le USB male micro USB adapter Supplied with the device KNT A KILOG 2015 Software The Kilog 2015 configuration and data processing software allows to configure save and process your data in a very simp...

Page 15: ......

Page 16: ...modify the characteristics of our products without prior notice Once returned to KIMO required waste collection will be assured in the respect of the environment in accordance to guidelines relating...

Reviews: