TOS9200/9201
Using Terminals and Connectors 4-5
4.2.1
Speci
fi
cations for the SIGNAL I/O connector
■
Input signal
Lo
w acti
v
e control input
High-le
v
el input v
oltage:
11
V to 15
V
Lo
w-le
v
el input v
oltage:
0
V to 4
V
Lo
w-le
v
el
A
C current:
Maximum –5 mA
Input interv
al:
Minimum 5 ms
■
Output signal
Open drain output
Output withstanding v
oltage
: DC 30
V
Output saturation v
oltage
:
Approximately 0.7
V (25
˚
C)
Maximum output current
: 400 mA (T
O
T
AL)
■
Pin assignment
T
ab
le4-1
SIGNAL I/O assignment
No
.
Signal name
I/O
Details of signal
1
PM0
I
LSB
LSD
2-digit BCD lo
w acti
v
e input
Signal input terminal for selection between the
panel memory for
A
CW
, DCW
, and IR, and the
program memory for
A
UT
O
Memory recall by latching this selection signal at
the rise of the strobe signal
2
PM1
I
3
PM2
I
4
PM3
I
5
PM4
I
MSD
6
PM5
I
7
PM6
I
8
PM7
I
MSB
9
STB
I
Input terminal for the strobe signal of the panel memory and program
memory
10
MODE0
I
Selects a test mode
2-bit lo
w acti
v
e input
MODE0
H
L
H
L
11
MODE1
I
MODE1
H
H
L
L
T
est mode
A
CW
DCW
IR
A
UT
O
12
NC
13
COM
Circuit common (chassis potential)
14
H.V ON
O
ON during a test and an automatic test (A
UT
O) or while a v
oltage
remains between the output terminals
15
TEST
O
ON during a test (e
xcept for v
oltage rise and v
oltage f
all)
16
P
ASS
O
ON during the time preset in the P
ASS HOLD settings when a P
ASS
judgement is made
17
U F
A
UL
O
Continuously ON in an UPPER F
AIL judgement. Continuously ON in
a CONT
A
CT F
AIL judgement with the scanner connected.
18
L F
A
UL
O
Continuously ON in an LO
WER F
AIL judgement. Continuously ON
in a CONT
A
CT F
AIL judgement with the scanner connected.
19
READ
Y
O
ON during the READ
Y status
20
PR
O
TECTION
O
ON when the PR
O
TECTION function is acti
v
ated
21
ST
AR
T
I
Input terminal for the ST
AR
T signal
22
ST
OP
I
Input terminal for the ST
OP signal
23
EN
ABLE
I
Input terminal for the EN
ABLE signal for the ST
AR
T signal
24
+24V
Output terminal for +24
V internal po
wer
, with a maximum output
current of 100 mA
25
COM
Circuit common (chassis potential)
9 8 7 6 5 4 3 2 1
13 12 11 10
19 18 17 16 15 14
24 23 22 21 20
25
PM7
PM6
PM5
PM4
PM3
PM2
PM1
PM0
H.V ON
TEST
PASS
U FAIL
L FAIL
READY
STB
MODE
MODE1
N.C
COM
COM
+24V
ENABLE
STOP
START
PROTECTION
Fig.4-3
SIGNAL I/O pin assignment
Summary of Contents for TOS9200
Page 22: ...P 10 Preface TOS9200 9201...
Page 116: ...3 78 Basic Operations TOS9200 9201...
Page 130: ...4 14 Using Terminals and Connectors TOS9200 9201...
Page 148: ...7 4 Maintenance TOS9200 9201...
Page 162: ...8 14 Specifications TOS9200 9201...
Page 170: ...I 4 Index TOS9200 9201...
Page 171: ......