64
TOS5200
Specifications
Unless specified otherwise, the specifications are for the following settings and conditions.
• The product is warmed up for at least 30 minutes.
• Values indicated by “TYP” are typical values. They are not guaranteed performance val-
ues.
• Values indicated by “rdng” are readout values.
• Values indicated by “set” are settings.
Withstanding voltage tester
TOS5200
AC output
section
Output range
0.05 kV to 5.00 kV
Setting
accuracy
± (2 % of set + 20 V) [at no load]
Setting range
0.00 kV to 5.50 kV
Resolution
10 V STEP
Max. rated output
1
500 VA (5 kV/100 mA)
Max. rated voltage
5 kV
Max. rated current
100 mA [output voltage 0.5 kV or higher]
Transformer rating
500 VA
Output voltage wave-
form
2
Sine
Distortion
If the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load
is connected).
Crest factor
Within
√
2 ± 3 % (output voltage 800 V or higher, at no load)
Frequency
50 Hz or 60 Hz
Accuracy
±0.5 % (excluding during voltage rise time)
Voltage regulation
10 % or less (when changing from maximum rated load to no load)
Input line regulation
±0.3 % (5 kV at no load; power supply voltage: 90 V to 250 V)
Short-circuit current
200 mA or more (output voltage 1.0 kV or higher)
Output method
PWM switching
Start voltage
The voltage at the start of withstanding voltage tests can be set to 50 % of the test volt-
age.
Limit voltage
The test voltage upper limit can be set. 0.00 kV to 5.50 kV.
Output voltage monitor feature
If output voltage exceeds the specified value + 350 V or is lower than the specified value -
350 V, output is turned off, and protective features are activated.
Voltmeter
Digital
Measurement
range
0.000 kV to 6.500 kV
Display
□
.
□□□
kV
Accuracy
V < 500 V: ± (1.5 % of r 20 V), V
≥
500 V: ±1.5 % of reading
Response
3
True rms/ Mean-value response rms display Can be switched
Hold feature
After a test is finished, the measured voltage is held until the PASS or FAIL judgment is
cleared.
Ammeter
Digital
Measurement
range
0.00 mA to 110 mA
Display
i = measured current
Accuracy
4
1.00 mA
≤
i: ± (1.5 % of reading), i < 1.00 mA: ± (1.5 % of r 30 µA)
Response
True rms/ Mean-value response rms display Can be switched
Hold feature
After a test is finished, the measured current is held until the PASS judgment is cleared.
i
< 1 mA
1 mA
≤
i
< 10 mA
10 mA
≤
i
< 100 mA
100 mA
≤
i
□
.
□□□
mA
□
.
□□□
mA
□□
.
□□
mA
□□□
.
□
mA
Summary of Contents for TOS5200
Page 7: ...TOS5200 7 C Test Start Operation and Display 75 D Troubleshooting 76 Index 79 ...
Page 18: ...18 TOS5200 This page is intentionally blank ...
Page 19: ...Installation and Preparation This chapter describes how to prepare this product for use ...
Page 60: ...60 TOS5200 This page is intentionally blank ...
Page 61: ...Maintenance This chapter explains daily inspections such as measurement checks ...
Page 78: ...78 TOS5200 This page is intentionally blank ...
Page 80: ...80 TOS5200 V version 2 Volt Error Protection 74 W W COMP 32 40 warm up time 64 ...
Page 81: ......