44
TOS5200
CONFIG Settings
CONFIG settings are provided on the CONFIG
screen and CONFIG
screen.
1
Press CONFIG (SHIFT+FUNCTION) to display the CONFIG setup screen.
Press once to show the CONFIG
screen and twice to show the CONFIG
screen.
2
Press MEMORY 2 or MEMORY 3 to move to the CONFIG item that you
want to set, and then use the rotary knob to set the value.
To exit from the CONFIG setup screen and return to the basic setup screen, press STOP.
If you enter CONFIG settings again without first turning the power off, the screen that you pre-
viously were viewing will be displayed.
CONFIG 1 settings
On the CONFIG
setup screen, you can set the test mode and buzzer volume level.
CONFIG 1
CONFIG 2
Double Action Double action feature
H.V ON
Output when there is residual volt-
age or during testing
Momentary
Momentary feature
Test
Output during testing when the
test voltage is at the set value
Fail Mode
Fail mode feature
Pass
PASS judgment output
Pass Hold
PASS judgment result hold
time
Upper Fail
Output when upper limit judgment
is FAIL
Pass
Buzzer volume level for PASS
judgment
Lower Fail
Output when lower limit judgment
is FAIL
Fail
Buzzer volume level for FAIL
judgment
Ready
Output when READY is displayed
Baudrate
RS232C baud rate
Protection
Output during PROTECTION
mode
Talk Mode
Talk mode
Power ON
Output when the POWER switch
is on
1
2
ACW
FUNCTION
LOCAL
SHIFT
+
1
2
Memo
The first screen that is dis-
played when you perform
configuration settings is
called CONFIG setup
screen.
1
A
kV
M
ȍ
mA
CONFIG
RISE TEST
RMS AVE
MORE CAL RMT
MT
LIMIT
50Hz 60Hz
UPPER
LOWER W COMP
s
1
2
3
READY
TEST
PASS
FAIL
PROTECTION
FAIL judgment buzzer volume level setting
[0 to 9: 10 setting levels]
PASS judgment buzzer volume level setting
[0 to 9: 10 setting levels]
Talk mode setting [0: off, 1: on]
RS232C baud rate setting
[0: 9 600, 1: 19 200, 2: 38 400, 3: 57 600, 4: 115 200]
Fail mode function setting [0: off, 1: on]
Momentary function setting [0: off, 1: on]
Double action feature setting [0: off, 1: on]
Judgment result hold time setting
[0: 50 ms, 1: 100 ms, 2: 200 ms, 3: 1 s, 4: 2 s, 5: 5 s, 6: HOLD]
1
MEMORY
2
3
RECALL
Example: Selecting the double action feature
(blinking)
Summary of Contents for TOS5200
Page 7: ...TOS5200 7 C Test Start Operation and Display 75 D Troubleshooting 76 Index 79 ...
Page 18: ...18 TOS5200 This page is intentionally blank ...
Page 19: ...Installation and Preparation This chapter describes how to prepare this product for use ...
Page 60: ...60 TOS5200 This page is intentionally blank ...
Page 61: ...Maintenance This chapter explains daily inspections such as measurement checks ...
Page 78: ...78 TOS5200 This page is intentionally blank ...
Page 80: ...80 TOS5200 V version 2 Volt Error Protection 74 W W COMP 32 40 warm up time 64 ...
Page 81: ......