36
PWX
CONFIG Settings
Use the CONFIG settings to set the PWX750ML system configuration. You can set and dis-
play the following parameters in the CONFIG settings. The CONFIG parameters are listed in
a separate document (included with this manual).
Effects:
●
indicates a parameter that may be affected when the panel settings are reset (CF00) or when a
preset memory entry is loaded.
▼
indicates a parameter that may be affected when the master unit, the slave unit, or the number
of units is changed (CF01).
In the “Note” column, “A” indicates a parameter that is applied immediately, “B” indicates a parameter
that is applied when the PWX series is turned on, and “C” indicates a parameter that is applied when
CF34 is executed.
Display
switching
Parameter
number
Setting or display description
Effect
Note
SYSTEM
CF00
1
1
You can only specify this parameter when the PWX series is being used as a master unit.
Resets the panel settings
—
A
CF01
Master-slave parallel operation parameter
▼
B
CF02
1
Power-on status parameter
—
B
CF03
Method for clearing OHP, FAN, and AC-FAIL alarms
—
B
CF04
1
Memory content display parameter
—
A
CF05
1
CC control using an Vext or Rext
●
A
CF06
1
CV control using an Vext or Rext
●
A
CF07
1
CV/CC control range parameter
—
A
CF08
Range during voltage and current monitoring
—
A
CF09
1
External control parameter for turning output on and off
●
▼
A
CF10
1
External control logic parameter for turning output on and off
▼
A
CF11
Bleeder on/off parameter
—
A
CF12
1
Output-on startup state parameter
▼
A
CF13
Detection time of OCP activation
—
A
CF14
1
Current setting limit
●
▼
A
CF15
1
Voltage setting limit
●
▼
A
CF16
Panel display brightness setting
—
A
CF17
Communication monitor timer setting
—
A
INTERFACE CF20
Remote interface parameter
▼
B
CF21
Command language parameter
▼
B
CF22
Emulation parameter during remote control
▼
B
CF23
SCPI communication error display parameter
▼
A
CF24
Multichannel (VMCB) domain number parameter
▼
B
CF25
Multichannel (VMCB) channel number
▼
B
LAN
CF30
DHCP parameter
▼
B or C
CF31
AUTO IP address parameter
▼
B or C
CF32
MANUAL IP address parameter
▼
B or C
CF33
Resets the LAN interface settings (LCI)
▼
A
CF34
Restarts the LAN interface (REBOOT)
▼
A
CF35
IP address display (1)
▼
─
CF36
IP address display (2)
▼
─
CF37
IP address display (3)
▼
─
CF38
IP address display (4)
▼
─
CF39
MAC address display (1) and (2)
▼
─
CF40
MAC address display (3) and (4)
▼
─
CF41
MAC address display (5) and (6)
▼
─
CF42
SCPI-RAW protocol TCP port number
▼
B or C
USB
CF50
VID (vendor ID) display
▼
─
CF51
PID (product ID) display
▼
─
RS232C
CF60
RS232C baud rate parameter
▼
B
Parameter number,
CF (CONFIG)
+ a two-digit number
Setting display
Lit
CONFIG setting and
display examples
Summary of Contents for PWX750ML
Page 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Page 52: ...52 PWX This page is intentionally blank...
Page 80: ...80 PWX This page is intentionally blank...
Page 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 84: ...84 PWX This page is intentionally blank...
Page 99: ...Appendix A Options B Troubleshooting...
Page 106: ...106 PWX This page is intentionally blank...
Page 109: ......