PWX
87
Series Operation
Parallel
/Series Operation
4
Settings (series operation)
Setting the voltage and current
Set the voltage and current on each unit. The voltage that is output is the total of the voltages
of the two units. Set the current to the same value on the two units.
Setting the overvoltage protection (OVP) and overcurrent protec-
tion (OCP)
In series operation, you have to set the overvoltage protection (OVP) and overcurrent protec-
tion (OCP) on both units. Specify the same values on the two units.
Starting series operation
Turning the power on and off
Turn the POWER switch on unit 1 and unit 2 on or off.
Turning the output on and off
Press OUTPUT on unit 1 and unit 2 to turn the output on or off.
See
CAUTION
After you turn the POWER switch off, wait at least 10 seconds after the fan stops before you
turn the POWER switch back on. Repeatedly turning the POWER switch on and off at short
intervals can cause damage to the inrush current limiter. In turn, this will shorten the service
life of the POWER switch, internal input fuse, and other components.
Summary of Contents for PWX1500H
Page 10: ...10 PWX This page is intentionally blank...
Page 26: ...26 PWX This page is intentionally blank...
Page 88: ...88 PWX This page is intentionally blank...
Page 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 92: ...92 PWX This page is intentionally blank...
Page 120: ...120 PWX This page is intentionally blank...
Page 121: ...Appendix A Options B Troubleshooting...