PMX_MULTI
User’s Manual
13
Installation
Connecting the Power Cord
This product is designed as an equipment of IEC Overvoltage Category II (energy-consuming equipment
supplied from a fixed installation).
Protective conductor current (at 257.4 Vac, 60 Hz) : Approx. 1 mA.
1
Check that the AC power line meets the nominal input rating of the product.
The product can receive a nominal power supply voltage of 100 Vac, 117 Vac, 200 Vac, 217 Vac,
or 234 Vac at a frequency of 50 Hz or 60 Hz.
The supply voltage is set before factory shipment by a Kikusui ser-
vice engineer. A mark is indicated to the left of the appropriate volt-
age.
Be sure to check the nominal input rating before connecting the
power cord.
Example of 217 Vac supply voltage
2
Turn the POWER switch off ( ).
3
Connect the power cord to the AC INPUT inlet on the rear panel.
4
Connect the power cord plug to an outlet with a ground terminal.
This completes the connections.
WARNING
Risk of electric shock.
• This product is IEC Safety Class I equipment (equipment with a protective conduc-
tor terminal). To prevent electric shock, be sure to connect the protective conductor
terminal of the product to electrical ground (safety ground).
• The product isp grounded through the power cord ground wire. Connect the protec-
tive conductor terminal to earth ground.
• Use the supplied power cord to connect to the AC line.
If the supplied power cord cannot be used because the rated voltage or the plug shape is
incompatible, have a qualified engineer replace it with an appropriate power cord that is 3
m or less in length. If obtaining a power cord is difficult, contact your Kikusui agent or dis-
tributor.
• The power cord with a plug can be used to disconnect the product from the AC power line
in an emergency.
• Secure adequate space around the power plug. Do not insert the power plug to an outlet
where accessibility to the plug is poor. And, do not place objects near the outlet that would
result in poor accessibility to the plug.
• Do not use the supplied power cord with other instruments.
50-60Hz
LINE
VOLTAGE
100V
117V
200V
217V
234V
SETTING
SUPPLY