26
Operation Manual
PFX2731S
Preparation | Preparing for Connecting a DUT
Constructing temperature measurement cable
1
Insert the temperature measurement cable into the connector on the temperature
measurement box.
Orient the temperature measurement box so that the
▼
symbol faces upward and connect the
cable to the temperature measurement box with the arrow mark aligned with the
▼
symbol.
2
Connect the thermocouple to the thermocouple connector on the temperature
measurement box.
Connect the thermocouple using two portions in the center of the thermocouple connector.
The thermocouples have polarities. Connect the positive (+) thermocouple to +TC and the negative
(-) thermocouple to -TC.
Remove the insulation of the thermocouple 10 mm from the end, firmly secure it so that it will not
come off from the connector.
Insert the connector
with the arrow faced upward.
▼
▼
・・
・
・
NC
+ TC
−
TC
NC
▼
・・
・
・
NC
+ TC
−
TC
NC
10 mm
While pushing
this part with a
screwdriver or other
fine-tipped tool, insert
the thermocouple wire.
Thermocouple
(+: red)
Thermocouple
(-: white)