114
PFX2512
8Slot Unit SL01-PFX Specifications
Items not listed are the same as those of the PFX2512.
Input voltage range
90 Vac to 250 Vac, 50 Hz/60 Hz
Power consumption
60 VAmax (when 8 OP03-PFXs are installed: 80 VAmax)
Operating temperature and humidity range 0 °C to 40 °C (32 °F to 104 °F), 20 %rh to 85 %rh (no
condensation)
Storage temperature and humidity range
-10 °C to 60 °C (14 °F to 140 °F), 0 %rh to 90 %rh (no
condensation)
Operating environment
Indoors, overvoltage category II
Altitude
Up to 2000 m
Number of slots
8
Compatible boards
1
1
OP02-PFX cannot be installed.
Voltmeter Unit OP03-PFX
Interface
LAN (Ethernet)
2
PC connection
2
IP address setting is either a fixed IP address (address that results by adding 20 to the PFX2512 address is
automatically assigned) or an IP address automatically assigned by a DHCP server.
Protocol
TCP-IP 10Base-T/100Base-TX
Connector
RJ-45 Connection/link activity LED
Sync connector
EX01-PFX connection
Sync in
1 input; measurement sync signal input
3
14-pin flat cable connector
3
Connects to an extension board.
Sync out
1 output; measurement sync signal output
(option for unit cascade connection)
14-pin flat cable connector
Safety
4
4
Does not apply to specially ordered or modified SL01-PFXs.
Complies with the requirements of the following directive and
standards.
Low Voltage Directive 2014/35/EU
5
EN 61010-1 (Class I
6
, Pollution Degree 2
7
)
5
Limited to products that have the CE/UKCA mark on their panels.
When the optional OP03-PFX Voltmeter Unit is used, compliance is achieve by using the optional TL12-PFX
sensing cable (length: approx. 3 m, connector area: with cover, with core).
6
This is a Class I equipment. Be sure to ground the SL01-PFX's protective conductor terminal. The safety of
this product is only guaranteed when the product is properly grounded.
Electromagnetic compatibility (EMC)
4
5
Complies with the requirements of the following directive and
standards.
EMC Directive 2014/30/EU
EN 61326-1 (Class A
8
)
EN 55011 (Class A
, Group 1
9
)
EN 61000-3-2
EN 61000-3-3
Applicable under the following conditions
The maximum length of all cabling and wiring connected to
the SL01-PFX is less than 3 m.
Dimensions, weight
See the outline drawing. Approx. 5 kg (11.02 Ib)
Accessories Power cord
100 V System
1 pc.
200 V System
1 pc.
EX01-PFX
10
1 pc. extension board (for installing in a PFX2512 slot)
LAN cable
1 pc. Straight type
14-core flat cable
1 pc.
Ferrite core for 14-core flat
cable
1 pc.
Lock lever
2 pcs.
Handling of the product
1 copy
Summary of Contents for PFX2500 Series
Page 12: ...12 PFX2512 This page is intentionally blank ...
Page 62: ...62 PFX2512 This page is intentionally blank ...
Page 71: ...Specifications This chapter provides the PFX2512 s specifications and outline drawing ...
Page 96: ...96 PFX2512 This page is intentionally blank ...
Page 140: ...140 PFX2512 Troubleshooting This page is intentionally blank ...
Page 143: ......