102
PFX2512
Connecting to the PFX2512
Using the included 14-core flat cable and the EX01-PFX connection board, connect the SL01-PFX to
the PFX2512.
1
Check that all devices that you will connect are turned off.
2
Install the EX01-PFX in the leftmost available option slot on the PFX2512.
If OP02-PFX units are installed, install the EX01-PFX in the leftmost available slot to the
right of the OP02-PFX units.
3
Attach the included lock lever and ferrite core to the included 14-core flat
cable.
The connector may fall out if you do not attach the lock lever.
4
Connect the ferrite core end of the 14-core flat cable to the SYNC IN connector
on the SL01-PFX rear panel.
Check that it does not fall out.
SYNC IN
connector
SYNC OUT
connector
14-core
flat cable
OP03-PFX
EX01-PFX
SL01-PFX
PFX2512
Install the EX01-PFX in the leftmost available option slot of the PFX2512.
If OP02-PFX units are installed, install the EX01-PFX in the leftmost available slot to the right of the
OP02-PFX units.
Lock lever
Ferrite core
14-core flat cable
SL01-PFX