PCZ1000A
3-15
3
Ope
ration
3.5.3
Constant Power (CP) Mode
Constant power (CP) mode works by setting a power limit value (W).
Setting range for power limit: 50 W to 1000 W
Fig.3-5 shows the front panel display when set to constant power mode. The input
terminal measurements are displayed on the upper side.
Fig.3-5
Display is CP Mode
1
If the LED above the LOAD key is on, press the LOAD key to change to
load-off.
2
Press the P SET key to enable CP mode.
The C.C and C.R LEDs illuminate.
3
Use the rotary knob to set the power limit value.
4
Press the LOAD key to change to the load-on state.
The LED above the LOAD key illuminates and current flow starts.
0.00Ar 0.0Ap 179.6V
-- PSET 1050W --
RMS current value
Peak current value
RMS voltage value
Power limit
0.00Ar 0.0Ap 179.6V
-- PSET 1050W --
0.00Ar 0.0Ap 179.6V
-- PSET 800W --
4.46Ar 6.3Ap 179.4V
-- PSET 800W --