KIKUSUI Electronics Corp.
94
FETC:<meas-item>/ MEAS:<meas-item>
Queries the scalar measurement data specified with <meas-item>.
Command
FETCh[:SCALar]:<meas-item>? [(@chanlist)]
MEASure[:SCALar]:<meas-item>? [(@chanlist)]
Measurement <meas-item> list of each phase
Phase designation (@chanlist) possible
<meas-item>
Description
Unit
ALL
All (the 25 items below)
CURRent:AC
Rms current without a DC component
Arms
CURRent:ACDC
Rms current
Arms
CURRent:AMPLitude:MAXimum
Current peak value
A
CURRent:AMPLitude:MAXimum:HOLD
Hold value of peak current
A
CURRent:CREStfactor
Current crest factor
̶
CURRent[:DC]
Average current
A
FREQ
Frequency
HZ
POWer[:DC]
Average power
W
POWer:AC[:REAL]
Power without a DC component
W
POWer:AC:APParent
Apparent power without a DC component
VA
POWer:AC:REACtive
Reactive power without a DC component
VAR
POWer:AC:PFACtor
Power factor without a DC component
̶
POWer:ACDC[:REAL]
Power
W
POWer:ACDC:APParent
Apparent power
VA
POWer:ACDC:REACtive
Reactive power
VAR
POWer:ACDC:PFACtor
Power factor
̶
VOLTage[:DC]
Average voltage
V
VOLTage:AC
Rms voltage without a DC component
Vrms
VOLTage:ACDC
Rms voltage
Vrms
VOLTage:AMPLitude:MAXimum
Voltage peak value
V
VOLTage:AMPLitude:MAXimum:HOLD Hold value of peak voltage
V
LTLVoltage:DC
Average line voltage
V
LTLVoltage:AC
Rms line voltage without a DC component Vrms
LTLVoltage:ACDC
Rms line voltage
Vrms
LTLVoltage:AMPLitude:MAXimum
Line voltage peak value
V