PAN-A
4-19
Chap
.4
Applied Oper
ation
1
• To minimize the in
fl
uence of noise on the output, use a 2-core
shielded wire or a twisted-pair wire to connect the control ter-
minals and Rext. If using a shielded wire, connect the shield
to the + (pos.) output terminal.
Note that longer lengths of wiring result in more susceptibil-
ity to the effects of noise; use of cables with anti-noise mea-
sures may not solve the problem.
• Approx. 0.4 mA of current always
fl
ows in Rext. For Rext,
use a 1/2 W or larger metal
fi
lm or wire-wound type resistor
with a good temperature coef
fi
cient and small aging effect.
5. Re-check that the connections on the terminal board and
the switch settings are correct.
Before controlling output current using the external resistor, re-adjust
the current system of the unit. For the adjustment procedure, see "6.3
Adjustment".
Fig.4-13
Connection and setup for output current con-
trol using external resistor
NOTE
2
7
8
13
14
19
1
2
3
4
5
6
7
8
9
10
S1
S2
S3
S4
S5
OVP
11
Rear OUTPUT terminal
board (PAN16-50A)
Rear CONTROL
terminal board
Rear OUTPUT
terminal board
Front control panel
[8]
[9]
Rext
Output current Io
≈
Imax • Rext
10 000
[A]
Rext
≤
10 000 [
Ω
]
Imax: max. output current[A]
(105 % of rated output current)
Set S3 to the lower position
and S4 to the upper position.
2-core shielded wire or
twisted-pair wire
Summary of Contents for PAN 110-1.5A
Page 4: ...II PAN A...
Page 44: ...2 12 PAN A...
Page 106: ...4 46 PAN A...
Page 156: ...7 26 PAN A...
Page 159: ......