332
KHA3000
Controlling the AC Power Supply
Setting the AC Power Supply
SOUR:OUTP
Sets the output of the AC power supply to on or off.
Command
SOURce:OUTPut[:STATe] {ON|OFF|1|0}
SOURce:OUTPut[:STATe]?
Parameter Value:
ON(1)
On
OFF(0)
Off (default)
Response
Returns the setting (ON/OFF) of the output of the AC power supply in the <NR1> format.
SOUR:PHAS:ON
Sets the ON phase of the output of the AC power supply.
Command
SOURce:PHASe:ON <NRf>
SOURce:PHASe:ON?
Parameter Value:
0 to 360
-1 (no specification)
Unit:
DEG
Response
Returns the ON phase of the output of the AC power supply in the <NR3> format.
SOUR:FREQ
Sets the frequency of the AC power supply.
Command
SOURce:FREQuency <NRf>
SOURce:FREQuency?
Parameter Value:
50 or 60
Unit:
Hz
Response
Returns the frequency of the AC power supply in the <NR3> format.
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...