328
KHA3000
Querying Measurement Data
FETC:CURR:HARM:PHAS
READ:CURR:HARM:PHAS
MEAS:CURR:HARM:PHAS
Each queries the phase angle of harmonic current.
Command
FETCh[<channel#>][:SCALar]:CURRent:HARMonics:PHASe?
{ALL|<NRf>}
READ[<channel#>][:SCALar]:CURRent:HARMonics:PHASe?
{ALL|<NRf>}
MEASure[<channel#>][:SCALar]:CURRent:HARMonics:PHASe?
{ALL|<NRf>}
Parameter Value:
1 to 40 (harmonic measurement mode)
1 to 180 (FFT analyzer)
“ALL” queries data of all orders.
Response
Returns the phase angle of <NRf>th-order harmonic current in the <NR3> format for
FETC:CURR:HARM:PHAS? <NRf>, READ:CURR:HARM:PHAS? <NRf> and
MEAS:CURR:HARM:PHAS? <NRf>.
Returns the phase angles of harmonic current of all orders in the <NR3>, <NR3> ... format
for FETC:CURR:HARM:PHAS? ALL, READ:CURR:HARM:PHAS? ALL and
MEAS:CURR:HARM:PHAS? <ALL>.
Unit:
DEG
Querying a Momentary Flicker Value
FETC:FLIC:ST
READ:FLIC:ST
MEAS:FLIC:ST
Each queries a momentary flicker value.
Command
FETCh[<channel#>][:SCALar]:FLICker:ST?
READ[<channel#>][:SCALar]:FLICker:ST?
MEASure[<channel#>][:SCALar]:FLICker:ST?
Response
Returns the momentary flicker value in the <NR3> format.
Unit:
None
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...
Page 391: ......