252
KHA3000
Basic Measurement
The set items are also applied to the settings of "V/I Waveform" on page 164 and "In-rush
Current Measurement" on page 262.
Used for observation and analysis. The sigma (
) value is an average or total sum. Refer to
the appendix for the calculation formula.
8
Select View Items
Select an item to be displayed. Select it with the small knob and press
the ENTER key. Every time the ENTER key is pressed, the check mark
turns on or off. Multiple checkboxes can be selected.
–
Voltage rms
Effective value of input voltage
Voltage Peak +
Positive amplitude peak value of input voltage
Voltage Peak -
Negative amplitude peak value of input voltage
Current rms
Effective value of input current
Current Peak +
Positive amplitude peak value of input current
Current Peak -
Negative amplitude peak value of input current
Frequency
Input frequency measured with input voltage
Real Power
*1
(W)
Real power (W) of the EUT
Apparent Power
*1
(VA) Apparent power (VA) of the EUT
Reactive Power
*1
(var) Reactive power (var) of the EUT
Power Factor
*1
Power factor of the EUT
THC
Total harmonic current of input current, effective
value of all the harmonic current components
from the 2nd to 40th order
POHC
Odd-order harmonic current of input current,
effective value of odd-order harmonic current
components from the 21st to 39th order
THD
Total harmonic distortion factor of input current,
effective value ratio of all the harmonic current
components from the 2nd to the 40th order
against the effective value of the fundamental
components
PWHD
Partial-weighted harmonic distortion factor of
input current, effective value ratio of all the
harmonic current components from the 14th to
40th order against the effective value of the
fundamental components
9
Scroll
Displayed when there are too many items to be displayed
simultaneously. Use this item to see the hidden portion of the screen.
Turn the small knob to vertically move the screen. This item is used in 2-
screen view mode.
–
10
Check View Phase
Select a phase to be displayed. Select it with the small knob and press
the ENTER key. Every time the ENTER key is pressed, the check mark
turns on or off. Multiple checkboxes can be selected.
L1, L2, L3
11
Return
Terminates the view setting.
–
12
Return to Top Menu
Returns to top menu of Other Measurement.
–
13
Prev/Next
Page 1/3
Switches to another menu page.
–
*1 In a three-phase three-wire connection, the
(sigma) values are the valid values. The values of each phase (L1 to L3)
carry no meaning, so they are displayed as "-----."
F key: Function key. You can also use the ESC key to return.
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...
Page 391: ......