118
KHA3000
Controlling the AC Power Supply
The AC power sources that this product can directly control are PCR-LE and PCR-LA
1
. PCR-
WE is controlled by the separately sold application software SD006-KHA Harmonics
Analyzing Suite.
Setting the AC Power Supply
To establish communication with the AC Power Supply, set the communication parameters
from the AC power supply panel as shown below.
Showing the External Control Display
�
Press the EXT CONT key.
The External Control display appears.
1.
PCR-LA with firmware version 3.32 or 3.33 cannot be used.
PCR-LE
PCR-LA
A shaded area indicates
a set value.
Baudrate:
9600 bps/ 19200 bps/ 38400 bps
Data:
8 bits / 7 bits
Stop:
1 bit / 2 bits
Parity: None
(fix)
Flow Ctrl:
OFF / RTS
・
CTS
0 8 1 1
A shaded area indicates
a set value.
Baud rate
1: 9 600 bps
2: 19200 bps
Data length
7: 7 bits
8: 8 bits
Parity
0: None
1: Odd
2: Even
number
number
Stop bit
1: 1 bit
2: 2 bits
WARNING
•
To prevent an electric shock, do not touch the SOURCE and LOAD terminals of this
product.
•
Do not touch the OUTPUT terminal of the AC Power Supply.
•
Do not touch the INPUT and OUTPUT terminals of the Line Impedance Network.
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...
Page 391: ......