6-26
KHA1000
6.4.2
Printout of Setting Values (Test Conditions)
This section indicates the printout format for the setting values (test conditions).
Items differ depending on the test conditions.
Fig.6-9
Example of test conditions printout
Table 6-3
Explanation of test conditions items
Voltage Fluctuation and Flicker Test Condition Report
Memo
Model name
Type
Serial No.
d measuring method
Pst Auto
Voltage Range
300 V
Current Range
20 A
Nominal voltage
230 V
Nominal frequency
50 Hz
Overrange Abort
Enabled
dmax limit value
6 %
Pst Measurement Time(s)
Pst Measurement Count
600 s
12 times
Flicker Margin
100 %
d Margin
100 %
Item
Content
Explanation
Memo
Memo
Data input by view type of HA-
Observation and Analysis window
Results List, Voltage Fluctuation List
View Setting
Model Name
Model name of EUT
Type
Type of EUT
Serial No.
Serial No. of EUT
d measuring method d measurement method
d measurement method input when
setting the test conditions
Voltage Range
Voltage range
Voltage range input when setting the test
conditions
Current Range
Current range
Current range input when setting the test
conditions
Nominal voltage
Nominal voltage
Nominal voltage input when setting the
test conditions
Nominal frequency
Nominal frequency
Nominal frequency input when setting the
test conditions
Overrange Abort
Setting of Ends when over-range
Whether or not to “Overrange Abort”
specified when setting the test conditions
dmax limit value
dmax limit value
dmax limit value input when setting the
test conditions
Time of d meas.
1-segment measurement time for d
measurement in Manual mode
d measurement time input when setting
the test conditions
Number of d meas.
1-segment measurement count for d
measurement in Manual mode
d measurement count input when setting
the test conditions
Flicker Margin
Flicker margin
Margin for the Pst and Plt limit values
input when setting the test conditions
d Margin
d margin
Margin for the limit values of dc, dmax,
and Tmax
*1
input when setting the test
conditions
Pst Measurement
Time(s)
Pst measurement time
Pst measurement time input when setting
the test conditions
Pst Measurement
Count
Pst measurement count
Pst measurement count input when
setting the test conditions
*1.Displayed as d(t)>3.3% depending on the selected standard.
Summary of Contents for KHA1000
Page 1: ...Part No Z1 003 482 I0043901 Oct 2021 Operation Manual Harmonic Flicker Analyzer KHA1000 ...
Page 8: ...vi KHA1000 ...
Page 20: ...xviii KHA1000 Rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 22: ...xx KHA1000 ...
Page 23: ...Overview This chapter provides an overview of the product and explains its features 1 ...
Page 30: ...1 8 KHA1000 ...
Page 68: ...3 20 KHA1000 ...
Page 69: ...Basic Operation This chapter explains basic operation methods 4 ...
Page 156: ...5 54 KHA1000 ...
Page 260: ...9 6 KHA1000 ...
Page 261: ...Specifications This chapter explains the specifications of this product 10 ...
Page 272: ...I 4 KHA1000 ...
Page 273: ......