1 G e n e r a l   i n f o r m a t i o n s

1.1 Informations for your safety

We are pleased that you have decided for a high-class KIESELMANN GmbH product. With correct
application and adequate maintenance, our products provide long time and reliable operation.

Before installation and initiation, please carefully read this instruction manual and the security ad-
vices contained in it. This guarantees reliable and safe operation of this product and your plant re-
spectively. Please note that an incorrect application of the process components may lead to great
material damages and personal injury.

In case of damages caused by non observance of this instruction manual, incorrect initiation, hand-
ling or external interference, guarantee and warranty will lapse!

Our products are produced, mounted and tested with high diligence. However, if there is still a
reason for complaint, we will naturally try to give you entire satisfaction within the scope of our war-
ranty. We will be at your disposal also after expiration of the warranty. In addition, you will also find
all necessary instructions and spare part data for maintenance in this instruction manual. If you
don't want to carry out the maintenance by yourself, our KIESELMANN GmbH - service team will
naturally be at your disposal.

1.2 Marking of security instructions

Hints are available in the chapter "safety instructions" or directly before the respective operation in-
struction. The hints are highlighted with a danger symbol and a signal word. Texts beside these
symbols have to be read and adhered to by all means. Please continue with the text and with the
handling at the valve only afterwards.

Symbol

Signal word

Meaning

DANGER

Imminent danger which will result severe personal injury or
death.

WARNING

Imminent danger which may result severe personal injury or
death.

CAUTION

Dangerous situation which may cause slight personal injury or
material damages.

NOTICE

An harmful situation which may result in damages of the product
itself or of adjacent vicinity.

INFORMATION

Marks application hints and other information which is particu-
larly useful.

1.3 General designated use

The fitting is designed exclusively for the purposes described below. Using the fitting for purposes
other than those mentioned is considered contrary to its designated use. KIESELMANN GmbH can-
not be held liable for any damage resulting from such use. The risk of such misuse lies entirely with
the user. The prerequisite for the reliable and safe operation of the fitting is proper transportation
and storage as well as competent installation and assembly. Operating the fitting within the limits
of its designated use also involves observing the operating, inspection and maintenance instruc-
tions.

1.4 Personnel

Personnel entrusted with the operation and maintenance of the tank safety system must have the
suitable qualification to carry out their tasks. They must be informed about possible dangers and
must understand and observe the safety instructions given in the relevant manual. Only allow quali-
fied personnel to make electrical connections.

www.sks-online.com 

www.sks-webshop.com

Summary of Contents for 6164

Page 1: ...Operating instruction Translation of the original Vacuum valve Type 6164 DN 50 DN 250 P D F a k 2 7 0 3 2 0 1 9 GB ENGLISH www sks online com www sks webshop com...

Page 2: ...MANN GmbH Paul Kieselmann Str 4 10 75438 Knittlingen 49 0 7043 371 0 7 49 0 7043 371 125 www kieselmann de info kieselmann de Copyright KIESELMANN FLUID PROCESS GROUP www sks online com www sks websho...

Page 3: ...torage 7 4 Function and operation 8 4 1 Description of function 8 4 2 Commissioning service and maintenance 8 4 2 1 Commissioning 8 4 2 2 General welding guidelines 8 4 2 3 ATEX Guidelines 8 4 2 4 Ser...

Page 4: ...e hints are highlighted with a danger symbol and a signal word Texts beside these symbols have to be read and adhered to by all means Please continue with the text and with the handling at the valve o...

Page 5: ...e original spare parts and accessories recommended by the manufacturer 1 6 General instructions The user is obliged to operate the fitting only when it is in good working order In addition to the in s...

Page 6: ...discharge arrangement b Carry the disassembling only if when the plant has been rendered pressure less and free of li quid and gas WARNING Functional impairment at low temperatures Low operating or a...

Page 7: ...duct due to improper storage Observe storage instructions avoid a prolonged storage INFORMATION Recommendation for longer storage We recommend regularly checking the product and the prevailing storage...

Page 8: ...ally install vertical as shown in the picture 4 2 2 General welding guidelines Sealing elements integrated in weld components must generally be removed prior to welding To prevent damage welding shoul...

Page 9: ...ly original spare parts may be installed 4 2 5 Cleaning Cleaning The optimum cleaning is carried out with the tank or pipe cleaning 4 3 Pressure setting The vacuum valve is set at the factory by corre...

Page 10: ...ure Ambient temperature Operating temperature Sterilization temperature 4 to 45 C air 0 to 100 C medium dependent EPDM 140 C SIP 30 min Materials in product contact Stainless steel 1 4301 AISI 304 Sur...

Page 11: ...bar 76 76 76 76 104 DN 125 5 bar 76 76 76 104 104 DN 150 5 bar 76 76 104 104 DN 200 5 bar 76 104 104 DN 250 5 bar 104 104 5 4 heating system The heating of the vacuum valves via resistance heating ca...

Page 12: ...h bracket Unscrew the screws B and remove the bracket Unscrew the bolts Screw A Washer A Pneum actuator Sensor mounting boltBoldbolt Screw B Washer B Air supply splash guard Unscrew the set screw Remo...

Page 13: ...Housing with splash guard Tighten the plate B between soft jaws in a vice Unsrew with a fit round rod the shaft from the plate B Remove O ring Round rod shaft Plate Plate O ring 6 2 Assembly Thoroughl...

Page 14: ...lve basic version 1 7 8 11 10 12 13 16 15 H 5 4 3 17 9 F 14 2 6 1 Housing 2 Plate 3 Plate 4 O ring 5 O ring 6 Plain bearing 7 shaft 8 Set screw 9 Joint DN 65 DN 250 10 lever 11 Set screw 12 weight 13...

Page 15: ...splash guard H 7 8 11 10 12 13 16 15 2 21 5 4 23 9 F 14 3 20 A 22 17 19 18 6 26 1 25 24 18 boltBoldbolt 19 Inner splash guard 20 Allen screw 21 DN65 DN250 Housing with vat DN 50 Vat with O ring 22 sp...

Page 16: ...x M10 112 229 26 65 68 91 104 x 2 0 154 130 4 x M8 126 235 29 80 84 112 129 x 2 0 204 160 4 x M8 129 334 34 100 104 131 154 x 2 0 204 180 6 x M8 130 334 30 125 128 155 204 x 2 0 254 230 6 x M12 150 43...

Page 17: ...7 6164_EN 17 21 Version with pneumatic lifting device and splash guard D5 L4 L3 Dimensions mm DN D5 L3 L4 50 196 26 198 65 230 29 214 80 279 34 219 100 279 30 217 125 354 38 235 150 366 39 260 200 412...

Page 18: ...52 2304 083 050 170 65 2304 065 050 052 2304 087 050 170 80 2304 080 050 052 2304 111 050 170 100 2304 100 050 052 2304 130 050 170 125 2304 125 050 052 2304 152 050 170 150 2304 150 050 052 2304 183...

Page 19: ...asic version Flow capacity p DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 DN 250 mbar m h m h m h m h m h m h m h m h Flow capacity 5 50 147 230 366 405 470 1 332 2 199 10 141 208 326 517 765 957 1 8...

Page 20: ...112 15 173 255 400 634 937 1 173 2 311 3 815 20 200 295 462 733 1 083 1 356 2 671 4 409 25 224 330 517 820 1 212 1 517 2 990 4 934 30 245 361 567 899 1 329 1 664 3 278 5 140 35 265 391 613 972 1 437...

Page 21: ...pressure The manufacturer hereby states that the above product is considered as an incomplete machine in the sense defined in the Directive 2006 42 EC on Machinery The above product is exclusively in...