Operating Instructions
SEG
5 Mounting and dismounting
5
Mounting and dismounting
5.1
Scope of delivery
The pull-rope emergency stop switch type SEG is sup-
plied with a screwed cable gland (
11
) and a dummy plug
(
10
)
(exception: devices with UL approval,
see Section 4.5: „Device variants“, page 28
The screws used to fix pull-rope emergency stop switch
SEG to the substructure are not supplied. To fix it in
place, we recommend two hexagonal screws M10 in ac-
cordance with EN ISO 4017 with suitable threadlock pro-
tection to prevent loosening
Cables for electrical connection and the pull rope system
are not supplied with the pull-rope emergency stop
switch either
(see Section 5.2.5: „Pull-rope system",
Penetration of dirt and moisture!
When delivered, the cover is screwed on finger-tight.
For transportation and storage, the screwed cable
gland is sealed by a protective plug. The device is not
protected against penetration of dirt and moisture in ac-
cordance with the protection class specified in the tech-
nical data
The device may only be operated when all openings are
sealed with the screwed cable gland and the dummy
plug. Use only supplied screwed cable glands and dum-
my plugs, otherwise the tightness of the device cannot
be ensured.
!
Fig. 5-1:
Scope of delivery
11
10