21
JMNC Operating Instructions
5 Mounting and Dismounting
5.3.1
Connection Assignment
Fig. 5-3: Connection assignment
Terminal
JMNC
1
Pulse, indicator input (plus) (NAMUR)
2
GND, indicator input (minus)
3
not assigned
4
Pulse output
5
24 V DC, output
6
not assigned
7
not assigned
8
Relay contact closed
9
Relay contact open
10
Relay contact
11
Supply voltage: 230 V (AC) / 115 V (AC) or 24 V (DC)
12
base (
10
) with terminal strip
cable inlets (
15
)
terminals (
14
)
1
2
3
4
5
6
7
8
9
10
11
12