Kidde SMK23 Installer'S Manual Download Page 1

SMK

23 

Pattress

Surface Mount Pattress For models: 

123

I

, 123/9

HI

, 123/9

HILL

, 123/9

EI

, 223

I

, 223/9

I

223/9

ILL

, 223/9

HI

, 223/9

HILL

, 323

I

, 323/9

HI

, 323/9

HILL

Application

This surface mount pattress is for use with
KIDDE Fyrnetics, Hard Wired Smoke, Heat and
CO Alarms, where surface cabling is being
used, such as in retrofit applications. 

Usage

This is designed for installation by a qualified
electrician, in accordance with the current IEE
regulations. Failure to install correctly can result
in a fatal shock or fire hazard.

Alarms without battery back-up must be
connected direct to the Consumer Unit on a
separately fused spur – see current Building
Regulations. 

(AC models with battery back-up may be
connected off an adjacent lighting circuit).

Knock-outs on the underside and edge of the
pattress provide flexibility of cable entry, for
ease of use. A small rib on the edge of the
pattress lines up with a mark on the alarms
base plate, to ensure correct alignment.

Site and select alarm type in accordance with
manufacturer literature/manual shipped with
alarm. Also refer to Building Regulation
requirements if applicable, plus BS5839 Pt 6.

Isolate mains power before commencing work.

Never remove/refit the cable harness whilst
mains power is present.

Surface Mounting Kit

Installer’s Guide

Crossing line and neutral connections or line
and interconnect connections will fatally
damage all interconnected alarms invalidating
the guarantee.

Never Meggar Test an installation, without
disconnecting any connected alarms (this can
permanently damage the alarm and invalidates
the guarantee).

All interconnected alarms must be powered off
the same fuse/circuit breaker.

Total cable length between alarms must not
exceed 250m (273yds) and be 1.5mm in
diameter, 3 core and earth (BS6243Y).

Important Notes

As in illustration 1 (on reverse), bring mains
cabling into pattress terminal block via knock-
out selected and fix pattress to ceiling with 
2 screws. 

(If using dry lining box, select appropriate holes
on pattress and secure with machine screws.)

Wire in mains cabling to terminal block, looping
“earth” in and out.

Connect flying leads on alarm cable harness to
appropriate terminals and ensure polarity is
correct.

Install and test alarm by following guidance in
Installer Manual of alarm.

smk23UM/800

Reviews: