ATTENTION! The model SLED177iCA strobe light is designed to notify hearing impaired
individuals of impending danger, they have no detection means and MUST be used in
conjunction with operating Smoke, Heat, or Carbon Monoxide Alarms. 

The model SLED177iCA AC wire-in Strobe light can be directly interconnected with
Kidde 3-wire Smoke, Heat and CO alarms. It will produce an intermittent flash pattern
(approximately 4 flashes, followed by approximately 5 seconds off) when triggered by a
Carbon Monoxide alarm and flash every second when triggered by a smoke or heat
alarm. 

Thank you for purchasing this strobe light. It is an important part of your family’s home
safety plan. You can trust Kidde to provide the highest quality safety products. We know
you expect nothing less when the lives of your family are at stake.

For model: SLED177iCA 

P/N 1102-7202-00 EN Rev. A

Strobe

Light

For your convenience, write down the following information. If you call

our Product Support Line, these are the first questions you will be asked:

Strobe Light Model Number
(located on back of alarm):

Date Code (located on back of device): 

Date of Purchase:

Where Purchased:

SLED177iCA

Strobe Light User Guide

1102-7202-00_RevA_SLED177iCA_MAN_EN:_  2013.6.3  3:21 PM  Page 1

Summary of Contents for SLED177iCA

Page 1: ...ry second when triggered by a smoke or heat alarm Thank you for purchasing this strobe light It is an important part of your family s home safety plan You can trust Kidde to provide the highest qualit...

Page 2: ...NALING DEVICE INOPERATIVE WARNING THIS STROBE LIGHT IS EXTREMELY BRIGHT DO NOT LOOK DIRECTLY AT THE LIGHT WHEN THE LIGHT IS FLASHING NG CONTENTS OF THIS USER GUIDE 1 SPECIFICATIONS 2 APPLICATIONS 3 RE...

Page 3: ...e Alarm Models KN COSM ICA KN COSM IBCA CO Photo Smoke Alarm Models KN COPE ICA Carbon Monoxide Alarms Models KN COB ICB CA KN COB IC CA KN COP IC CA Strobe Light SL177i SLED177iCA Relay Modules SM120...

Page 4: ...r is kept closed at night an interconnecting smoke detector must also be installed in that bedroom Locate additional strobe lights in any lived in room where a hearing impaired individual would need t...

Page 5: ...wind derived power sources These power sources produce high peak voltages that will damage the strobe light CAUTION TURN OFF THE MAIN POWER TO THE CIRCUIT BEFORE WIRING THE STROBE LIGHT 1 When Strobe...

Page 6: ...ING DIAGRAM N N L WIRE NUT WIRE NUT OR OR EQUIVALENT EQUIVALENT WHITE WHITE BLACK BLACK RED RED WHITE WHITE RED RED BLACK BLACK WHITE WHITE WHITE WHITE RED RED RED RED BLACK BLACK BLACK BLACK FUSE OR...

Page 7: ...rness as described in the WIRING INSTRUCTIONS attach the mounting plate to the electrical box see fig 2 FIGURE 2 SELECT PROPER MOUNTING HOLES ON THE MOUNTING PLATE Use a screwdriver to punch out only...

Page 8: ...when the strobe is correctly powered TAMPER RESIST LOCKING PIN To make your strobe light tamper resistant a locking pin has been provided with your strobe light Using this pin will help deter individu...

Page 9: ...est sequence for the alarm The controlling alarm will also send an activation signal through the interconnecting wiring to the strobe light and cause the strobe light to flash if the strobe light and...

Page 10: ...THER SIDE OF A CLOSED DOOR ALARMS DO HAVE LIMITATIONS AC POWERED ALARMS WILL NOT OPERATE IF AC POWER HAS BEEN CUT OFF BY AN ELECTRICAL FIRE OR AN OPEN FUSE HOME EMERGENCIES DEVELOP IN DIFFERENT WAYS A...

Page 11: ...your home where you all can meet if a fire occurs Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it Practice a fire drill at least every six m...

Page 12: ...is all right to do so There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72 For instance a smoking in bed b leaving children home alo...

Page 13: ...ation of the smoke alarms in the kitchen attic finished or unfinished or garage is normally not recommended as these locations occasionally experience conditions that can result in improper operation...

Page 14: ...HIS VISUAL SIGNALING DEVICE OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF THE VISUAL SIGNALING DEVICE AND IN NO CASE SHALL Kidde OR ANY OF ITS PAR...