background image

1

WireLeSS

Photoelectric Smoke Alarm  

with Voice and Wireless Interconnect

User Guide

 

Model P4010DCS-WCA
Model P4010LDCS-WCA  

(Safety Light)

WireLeSS interconnect:

  

You do NOT need a home wi-fi 

system to use these units. Multiple 

wireless units create their own 

independent wireless alarm 

network.

 10-year battery
 WireLeSS interconnect
 Voice aLarM 

SMoKe aLarM

P/

N

: 0

31

4-7

20

2-

01

Summary of Contents for P4010DCS-WCA

Page 1: ...e Model P4010DCS WCA Model P4010LDCS WCA Safety Light WireLESS Interconnect You do NOT need a home wi fi system to use these units Multiple wireless units create their own independent wireless alarm network 10 year battery Wireless Interconnect VOICE ALARM SMOKE ALARM P N 0314 7202 01 ...

Page 2: ...lay with the unit Your Kidde Smoke Alarm was designed for use in a residential environment It is not designed for use in a recreational vehicle RV or boat Note Please take a few minutes to thoroughly read this user guide which should be saved for future reference and passed on to any subsequent owner The National Fire Protection Association NFPA and the manufacturer recommend replacing this alarm ...

Page 3: ...9 7 Recommended Locations For Smoke Alarms 10 8 Locations To Avoid 12 9 Activation And Wireless Alarm Network 13 9 1 Setting Up A Wireless Alarm Network 14 9 2 Adding Another Device to an Existing Wireless Alarm Network 16 9 3 Resetting a Device s Wireless Settings 18 10 Operation And Testing 18 11 Recognizing Nuisance Alarms 20 12 Battery 22 13 Permanently Disable Alarm Discharge Battery 23 14 Cl...

Page 4: ...t If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay close to the floor where the air is cleaner Crawl if necessary and breathe shallowly through a cloth wet if possible Once outside go to your selected meeting place and make sure everyone is there Call th...

Page 5: ...e of Carbon Monoxide CO at high concentrations which can kill you 1 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not re enter the premises nor move away from the open door window until the emergency services responders have arrived the premises have been aired out and your alarm remains in its normal condition 2 Cal...

Page 6: ...the initiating alarm unit Push test button to clear Alarm Memory NOTE standard test sequence will follow Push release button again to cancel test Smoke Alarm Hush Mode Hush Control Red LED blinks every 2 sec After button push Hush Mode Activated Smoke alarm pattern stops If there is too much smoke to allow Hush Voice Too Much Smoke Alarm cannot be Hushed Smoke alarm pattern continues This feature ...

Page 7: ...d of Unit Life Hush Mode after push release Test Hush button during End of Life Voice Temporarily Silenced End of Unit Life chirps silenced for 24 hrs 7 days after End of Unit Life chirps begin the chirps cannot be silenced Remove discharge dispose unit and replace as soon as possible Network Error Chime every 30 secs Voice every 30 sec Connection lost Press button to temporarily silence After 5 m...

Page 8: ...ling the unit Product Features and Specifications Temperature Operating Range 4 4 C 40 F to 37 8 C 100 F Humidity Operating range up to 95 RH non condensing Audible Alarm 85 dB at 10 3 0 to 3 5 KHz pulsing alarm with voice message Fire NOTE This is not a CO alarm but it will receive and transmit a CO alarm signal with voice message Warning Carbon Monoxide from an interconnected CO or combination s...

Page 9: ...on sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms A battery powered alarm must have a battery of the specified type in good condition and installed properly This model has a sealed battery Smoke al...

Page 10: ...r smoke alarms and smoke detectors on tray shaped ceilings 4 10cm 4 10cm 12 30 5cm 12 30 5cm ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings 4 10cm 4 10cm 12 30 5cm 12 30 5cm ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings 4 10cm 4 10cm 12 30 5cm 12 30 5cm 3 0 9m 3 0 ...

Page 11: ...y MA 02269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended on the previous page In older mobile homes that are not well insulated compared to present standards extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can ...

Page 12: ...alarm In very humid areas above 95 RH non condensing Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 0 9m 3ft of the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Near lights Electronic noise generated by the elect...

Page 13: ...he battery activation is a one time feature After activation the battery cannot be turned off and can only be discharged at the end of unit life If the alarm is removed from the mounting plate the backup battery will remain active See Permanently Disable Alarm Discharge Battery section Wireless alarm Interconnect Model Compatibility This model has wireless alarm interconnect capability When one wi...

Page 14: ...the Test button twice on ALL devices you wish to connect You should hear one beep for each button press followed by a voice message confirming your language selection English language selected or Langue française selectionné If no language is selected the voice prompts will continue in the default set language NOTE If no further steps are taken within 15 minutes of initial power up a voice prompt ...

Page 15: ...nd install alarm After selecting the proper location for your alarm attach the mounting bracket to the wall or ceiling To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting bracket must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direct...

Page 16: ...y a voice message confirming your language selection English language selected or Langue française selectionné If no language is selected the voice prompts will continue in the default set language D Pick One Installed Device Press and hold the button on ONE INSTALLED device on your network until you hear two beeps Release button You will hear Searching for other devices Light will pulse green and...

Page 17: ...e wall or ceiling To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting bracket must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Install the alarm fully on the mounting bracket by rotating the alarm in a clockwise direction NOTE The alarm will mount to the bracket in 4 positions every 90 degrees The alarm is now activat...

Page 18: ...larm network or Section 9 2 for adding this device to an existing alarm network NOTE If no further steps are taken within 15 minutes of resetting the unit s wireless settings a voice prompt No devices found not connected will be heard once and the wireless function will turn off The unit will then perform as a stand alone alarm See Section 9 2 for adding this device to an existing alarm network 10...

Page 19: ... shipment or disposal Warning Due to the loudness of the alarm always stand about 0 7 M 2 5 ft away from the unit or use ear protection when testing Warning DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire Smoke Alarm Memory If a unit experiences a smoke alarm event then the condition clears and the unit stops alarmin...

Page 20: ... LIFE OR LOW BATTERY MODE 11 Recognizing Nuisance Alarms Smoke Nuisance Hush If you know why the alarm is sounding and you can verify that it is not a life threatening situation you can push the button on the initiating unit green LED flashing every second to silence the alarm for 8 10 minutes If the smoke is not too dense that unit and all interconnected units will silence After the Hush period t...

Page 21: ...ystem all units will be alarming together a unit that detects smoke and initiates an alarm is called the initiating alarm unit Initiating alarm units will be flashing the Green LED every second during alarm Depending on unit locations and the location of the source of smoke it is possible to have more than one initiating unit If you suspect a nuisance alarm situation you can use this feature to he...

Page 22: ...tery backup system No battery installation or replacement is necessary for the life of the alarm IMPORTANT Constant exposure to high or low humidity or temperatures may reduce battery life WARNING NO SERVICEABLE PARTS INCLUDED DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is equipped with a low battery monitor circuit If the battery ...

Page 23: ...ill no longer function Once the alarm battery has been discharged the alarm cannot be mounted onto the mounting plate or reactivated To Permanently Disable Alarm Discharge Battery Rotate the alarm counterclockwise to remove it from the mounting plate Push in the dashed area with a screwdriver to break tab Figure 13 A After the tab is broken use the screwdriver to turn the red slotted arrow to the ...

Page 24: ...de and the Red LED is blinking a fault code of 10 or 14 flashes after a Test Hush button push the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not clear the alarm needs to be replaced Never use detergent or other solvents to clean the unit Avoid spraying air freshener hair spray or other aerosols near the alarm Do not paint the unit Paint will seal t...

Page 25: ... what to do in case of fire and where to meet after they leave the house Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sounds of the smoke alarm and...

Page 26: ...rotection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required smoke alarms The installatio...

Page 27: ...of each separate dwelling unit sleeping area within 6 4 m 21 of any door to a sleeping room with the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics 5 In the living area s of a guest suite 6 In the living are...

Page 28: ...his product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of any kind resul...