background image

1

IntellIgent WIre-Free

Smoke Alarm User guide

Photoelectric Smoke Alarm  
with Voice and Hardwire/Wireless Interconnect

Model P4010ACS-W  
Model P4010LACS-W (Safety Light)

WIre-Free Interconnect:

  

You do NOT need a home wi-fi system to use  
these units. Multiple wireless units create their  
own independent wireless alarm network.

 120V HArdWIre
 10-yeAr bAttery bAckUp
 HArdWIre & WIre-Free 

Interconnect

 VoIce AlArM 

SMoke AlArM

   

Summary of Contents for P4010ACS-W

Page 1: ...nterconnect Model P4010ACS W Model P4010LACS W Safety Light Wire Free Interconnect You do NOT need a home wi fi system to use these units Multiple wireless units create their own independent wireless...

Page 2: ...arm and that they should never play with the unit Your Kidde Smoke Alarm was designed for use in a residential environment It is not designed for use in a recreational vehicle RV or boat Note Please t...

Page 3: ...cations For Smoke Alarms 10 8 Locations To Avoid 12 9 Activation And Wireless Alarm Network 13 9 1 Setting Up A Wireless Alarm Network 13 9 2 Adding Another Device to an Existing Wireless Alarm Networ...

Page 4: ...it If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in If the escape route requires you to go through smoke stay cl...

Page 5: ...accounted for Alert small children in the home as well as anyone else that might have difficulty recognizing the impor tance of the alarm sounding or that might have difficulty leaving the area withou...

Page 6: ...After button push Smoke previously detected only on the initiating alarm unit Push test button to clear Alarm Memory NOTE stan dard test sequence will follow Push release button again to cancel test...

Page 7: ...nd of Unit Life Hush Mode after push release Test Hush button during End of Life Voice Temporarily Silenced End of Unit Life chirps silenced for 24 hrs 7 days after End of Unit Life chirps begin the c...

Page 8: ...nnected to obtain the full 10 year battery and unit life Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8 C Humidity Operating range up to 95 RH non condensing...

Page 9: ...nsing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow...

Page 10: ...the room Ceiling mounting is preferred in ordinary residential construction ANYWHERE ALONG THIS BOLD SURFACE Locations permitted for smoke alarms and smoke detectors on tray shaped ceilings ANYWHERE A...

Page 11: ...269 Mobile Home Installation Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compare...

Page 12: ...es and unfinished attics In dusty areas Dust particles may cause nuisance alarm or failure to alarm In very humid areas above 95 RH non condensing Moisture or steam can cause nuisance alarms In insect...

Page 13: ...ribed in Section 9 3 Once wireless settings are reset the unit will prompt the user to follow Quickstart instructions 9 1 Setting Up a Wireless Alarm Network Creating an interconnected wireless alarm...

Page 14: ...complete d RELAX AND WAIT Wait until all devices have connected to network Once connected each device will speak Success now connected Once connected the lights will glow green e Pick one device Pres...

Page 15: ...ase button You will hear Searching for other devices Light will pulse green and device will sound a continuous Sonar ping until step E is completed d Relax and wait Wait until the new device has conne...

Page 16: ...settings b Conclude reset Light ring will flash green once and then it will pulse red You will hear the words Ready to connect follow quick start instructions Device has been reset See Section 9 1 to...

Page 17: ...otected by a ground fault interrupter Smoke alarms are not to be used with detector guards unless the combination alarm and detector guard have been evaluated and found suitable for that purpose WARNI...

Page 18: ...nected system is 1000 feet Figure 5 illustrates interconnection wiring Improper connection will result in damage to the alarm failure to operate or a shock hazard Make certain alarms are wired to a co...

Page 19: ...ck connect harness or mounting bracket yet Go back to Section 9 ACTIVATION AND WIRELESS ALARM NETWORK If you are not using the wireless interconnect function or if you have finished wireless alarm set...

Page 20: ...er applying AC power to avoid false low battery notification NOTE The battery activation is a one time feature After activation the battery cannot be turned off and can only be discharged at the end o...

Page 21: ...COSM I KN COSM IB KN COSM IBA KN COPE I KN COPE IC KN COB IC KN COP IC SL177i SLED177i HD135F SM120X CO120X i12010S i12010SCO P4010ACSCO P4010ACSCO W P4010LACS W P4010ACS P4010ACS W Wireless alarm In...

Page 22: ...re working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Permanently Disable Alarm Discharge Battery section to determine how to prepare the u...

Page 23: ...use the unit is located in either a constantly dark or lighted location the chirps mentioned above will not be delayed at night Moving the unit to a different location might allow the unit to determin...

Page 24: ...OTE Dense smoke will override Hush and sound a continuous alarm If no fire is present check to see if one of the reasons listed in Locations to avoid may have caused the alarm If a fire is discovered...

Page 25: ...unit s will silence for two minutes You can use the LOCATE feature repeatedly until you find the initiating alarm unit s or the air has been cleared of the condition causing the alarm NOTE Hush and Lo...

Page 26: ...dity or temperatures may reduce battery life WARNING NO SERVICEABLE PARTS INCLUDED DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is equ...

Page 27: ...function Once the alarm battery has been discharged the alarm cannot be mounted onto the mounting plate or reactivated To Permanently Disable Alarm Discharge Battery Rotate the alarm counterclockwise...

Page 28: ...de and the Red LED is blinking a fault code of 10 or 14 flashes after a Test Hush button push the alarm may be in need of cleaning After cleaning press the Test Hush button If the fault does not clear...

Page 29: ...what to do in case of fire and where to meet after they leave the house Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice...

Page 30: ...seholder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not...

Page 31: ...the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmfu...

Page 32: ...acturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whethe...

Reviews: